Features

n

  Oscilloscope probe jack for output voltage and ripple measurements

n

  Simple to use

n

  Ring lug connections

Introduction

The Customer Evaluation Board offers a convenient means to evaluate the 
performance of Vicor’s high density converter (HDC) Brick module and has been 
optimized for user convenience. Please refer to the appropriate HDC datasheet for 
performance and operating limits. The datasheets are available for downloading at

 

vicorpower.com

.

 

Please refer to Figure 1 for locations of the input and output connections as viewed 
from the component side. Wires may be soldered directly to the pads instead of ring 
lugs if desired to minimize circuit impedances.  

NOTE: 

The Customer Evaluation Board has footprints for both A and B Series HDC modules, but only 

one module can be populated on the evaluation board.

HD Series Brick Evaluation Board 

USER GUIDE  |  UG:118

Written by: Michael DeGaetano 
Associate Product Line Engineer
July 2014

Contents Page

Features 1

Introduction 1

Set Up 

2

Recommended 3
Hardware 

Thermals 3

Ordering Info 

3

Test Point List 

4

Bill of Materials 

4

 

Содержание HD Series

Страница 1: ...ets are available for downloading at vicorpower com Please refer to Figure 1 for locations of the input and output connections as viewed from the component side Wires may be soldered directly to the pads instead of ring lugs if desired to minimize circuit impedances NOTE The Customer Evaluation Board has footprints for both A and B Series HDC modules but only one module can be populated on the eva...

Страница 2: ... short leads of suitable gauge to carry the output current and minimize losses The evaluation board can be connected directly to the application for which the module is intended However the interconnect impedances between the evaluation board and the application can greatly affect the transient response For applications where transient response is critical the user should consider mounting the HDC...

Страница 3: ...efficiency measurement Be certain to accurately measure the voltage directly at the HDC using the appropriate pair of contact points located at the corners of the HDC Recommended Hardware Qty Description Manufacturer P N 5 10 32 lock washer Kit 41062 5 10 32 screw 5 10 32 hex nut Kit 41062 is included with the Customer Evaluation Board Thermals For most lab environments a fan blowing across the ev...

Страница 4: ...X7T 0 68 µF 10 450 V 2220 TDK 445 7776 1 ND TDK C5750X7T2W684K 200KA C02 C03 C04 C05 CAP X7R 2200 pF 10 250 V 2220 Murata 490 3480 1 ND Murata GA355QR7GF222K W01L C06 C07 N A N A N A N A N A C11 C21 CAP X7R 22 µF 10 50 V 1206 AVX 478 1560 1 ND AVX 12065C224KAT2A C22 C23 C24 C25 C31 CAP ALEL 1000 µF 20 25V SMD 13 5 X 13 5 Panasonic PCE3462CT ND No Stock No Stock C33 CAP X7R 2200 pF 10 250 V 2220 Mu...

Страница 5: ...S02 R01 RES 374K OHM 1 8 W 1 0805 Panasonic P374KCCT ND Panasonic ERJ 6ENF3743V R02 R03 RES ZERO OHM JUMPER 2 A 1206 Vishay 541 0 0ECT ND Vishay CRCW 12060000Z0EC R04 N A N A N A N A N A R05 RES 23 7 OHM 1 8 W 1 0805 Panasonic P23 7CCT ND Panasonic ERJ 6ENF23R7V R08 RES 0 OHM JUMPER 1 A 0603 Panasonic P0 0GCT ND Panasonic ERJ 3GEY0R00V R10 N A N A N A N A N A R11 RES 20 OHM 1 4 W 1 1206 Panasonic ...

Страница 6: ...The Power Behind Performance Rev 1 0 07 14 vicorpower com Applications Engineering 800 927 9474 Page 6 Figure 2 HDC Customer Evaluation Board Schematic ...

Отзывы: