background image

 

UG:118 

vicorpower.com  

Applications Engineering: 800 927.9474 

Page 3

GND

The GND terminal of the Customer Evaluation Board is provided for basic conducted EMI 
testing of the HDC, during which it should be connected to earth ground.  

Output Voltage Measurement Jack (J103)

This connector is provided to make accurate measurements of the output voltage of the 
HDC. Many types of scope probes may be directly connected to this point if the probe is 
equipped with a removable plastic sheath. To avoid creating ground loops when making 
measurements of the output or input voltage, these measurements should be made 
separately.

Input Current Measurement

A current probe can be passed around the +IN lead connected to the HDC. 

Note:

 

The input filter consists of capacitors C01, C02, C03, C04 and common-mode inductors L100 and 

L101 on the Customer Evaluation Board. This filter is downstream of input current measurements.

Efficiency Measurement

As the HDC can deliver and consume large currents, the effect of the PCB must be 
considered when making an efficiency measurement. Be certain to accurately measure 
the voltage directly at the HDC using the appropriate pair of contact points located at the 
corners of the HDC.

Recommended Hardware:

Qty

Description

Manufacturer P/N

5

# 10-32 lock washer

Kit # 41062

5

# 10-32 screw

5

# 10-32 hex nut

Kit # 41062 is included with the Customer Evaluation Board.

Thermals

For most lab environments a fan blowing across the evaluation board is recommended. 
For additional thermal information regarding the HDC refer to the datasheet or contact 
Vicor Applications Engineering for assistance (800) 927-9474.

NOTE:

 

The HDC Customer Evaluation Board can operate between -20 to 100°C.

Caution

The HDC Customer Evaluation Board can comfortably operate at surface temperatures 
which may pose a thermal hazard to the operator. Be careful not to touch any exposed 
surface. HDCs may operate at potentially dangerous voltages and pose and energy 
hazard. The Customer Evaluation Board is not intended for use in end item equipment. 

Ordering Information

The Customer Evaluation Board is specified by replacing the “–00” suffix with “–CB” to 
the appropriate HDCC model number.

See:

 

http://www.vicorpower.com/dc-dc-converters-board-mount/hd-brick-dc-dc-

converters

 for model number listings.

Содержание HD Series

Страница 1: ...ets are available for downloading at vicorpower com Please refer to Figure 1 for locations of the input and output connections as viewed from the component side Wires may be soldered directly to the pads instead of ring lugs if desired to minimize circuit impedances NOTE The Customer Evaluation Board has footprints for both A and B Series HDC modules but only one module can be populated on the eva...

Страница 2: ... short leads of suitable gauge to carry the output current and minimize losses The evaluation board can be connected directly to the application for which the module is intended However the interconnect impedances between the evaluation board and the application can greatly affect the transient response For applications where transient response is critical the user should consider mounting the HDC...

Страница 3: ...efficiency measurement Be certain to accurately measure the voltage directly at the HDC using the appropriate pair of contact points located at the corners of the HDC Recommended Hardware Qty Description Manufacturer P N 5 10 32 lock washer Kit 41062 5 10 32 screw 5 10 32 hex nut Kit 41062 is included with the Customer Evaluation Board Thermals For most lab environments a fan blowing across the ev...

Страница 4: ...X7T 0 68 µF 10 450 V 2220 TDK 445 7776 1 ND TDK C5750X7T2W684K 200KA C02 C03 C04 C05 CAP X7R 2200 pF 10 250 V 2220 Murata 490 3480 1 ND Murata GA355QR7GF222K W01L C06 C07 N A N A N A N A N A C11 C21 CAP X7R 22 µF 10 50 V 1206 AVX 478 1560 1 ND AVX 12065C224KAT2A C22 C23 C24 C25 C31 CAP ALEL 1000 µF 20 25V SMD 13 5 X 13 5 Panasonic PCE3462CT ND No Stock No Stock C33 CAP X7R 2200 pF 10 250 V 2220 Mu...

Страница 5: ...S02 R01 RES 374K OHM 1 8 W 1 0805 Panasonic P374KCCT ND Panasonic ERJ 6ENF3743V R02 R03 RES ZERO OHM JUMPER 2 A 1206 Vishay 541 0 0ECT ND Vishay CRCW 12060000Z0EC R04 N A N A N A N A N A R05 RES 23 7 OHM 1 8 W 1 0805 Panasonic P23 7CCT ND Panasonic ERJ 6ENF23R7V R08 RES 0 OHM JUMPER 1 A 0603 Panasonic P0 0GCT ND Panasonic ERJ 3GEY0R00V R10 N A N A N A N A N A R11 RES 20 OHM 1 4 W 1 1206 Panasonic ...