Test Point List

Test

Point

Reference

Description

Comments

TP01

+HDC_IN

+IN of converter after input filter

TP02

FT

TP03

PC

TP05

-HDC_IN

-IN of converter after input filter

TP06

-OUT

TP07

SGND

TP09

FB

TP10

TR

TP11

VDDB

TP12

VDD

TP14

+OUT

TP52

+IN

TP51

-IN

Bill of Materials

Ref.

Desc.

Description

Digi-Key

Manufacturer

Digi-Key

Part #

Future

Manufacturer

Future

Part #

C01

CAP X7T 0.68 µF 
10% 450 V 2220

TDK

445-7776-1-ND

TDK

C5750X7T2W684K-

200KA

C02 

C03

C04

C05

CAP X7R 2200 pF 
10% 250 V 2220

Murata

490-3480-1-ND

Murata

GA355QR7GF222K-

W01L

C06

C07

N/A

N/A

N/A

N/A

N/A

C11

C21

CAP X7R .22 µF 
10% 50 V 1206

AVX

478-1560-1-ND

AVX

12065C224KAT2A

C22

C23

C24

C25 

C31

CAP ALEL 
1000 µF 20% 25V 
SMD 13.5 X 13.5

Panasonic

PCE3462CT-ND

No Stock

No Stock

C33

CAP X7R 2200 pF 
10% 250 V 2220

Murata

490-3480-1-ND

Murata

GA355QR7GF222K-

W01L

C34

F01

N/A

N/A

N/A

N/A

N/A

F02

FUSE 4 A 425 
VDC FAST 
3.6 X 11 SMD

No Stock

No Stock

No Stock

No Stock

F03

N/A

N/A

N/A

N/A

N/A

Table 1.

Test Point descriptions

Table 2.

Bill of materials

Содержание HD Series

Страница 1: ...ets are available for downloading at vicorpower com Please refer to Figure 1 for locations of the input and output connections as viewed from the component side Wires may be soldered directly to the pads instead of ring lugs if desired to minimize circuit impedances NOTE The Customer Evaluation Board has footprints for both A and B Series HDC modules but only one module can be populated on the eva...

Страница 2: ... short leads of suitable gauge to carry the output current and minimize losses The evaluation board can be connected directly to the application for which the module is intended However the interconnect impedances between the evaluation board and the application can greatly affect the transient response For applications where transient response is critical the user should consider mounting the HDC...

Страница 3: ...efficiency measurement Be certain to accurately measure the voltage directly at the HDC using the appropriate pair of contact points located at the corners of the HDC Recommended Hardware Qty Description Manufacturer P N 5 10 32 lock washer Kit 41062 5 10 32 screw 5 10 32 hex nut Kit 41062 is included with the Customer Evaluation Board Thermals For most lab environments a fan blowing across the ev...

Страница 4: ...X7T 0 68 µF 10 450 V 2220 TDK 445 7776 1 ND TDK C5750X7T2W684K 200KA C02 C03 C04 C05 CAP X7R 2200 pF 10 250 V 2220 Murata 490 3480 1 ND Murata GA355QR7GF222K W01L C06 C07 N A N A N A N A N A C11 C21 CAP X7R 22 µF 10 50 V 1206 AVX 478 1560 1 ND AVX 12065C224KAT2A C22 C23 C24 C25 C31 CAP ALEL 1000 µF 20 25V SMD 13 5 X 13 5 Panasonic PCE3462CT ND No Stock No Stock C33 CAP X7R 2200 pF 10 250 V 2220 Mu...

Страница 5: ...S02 R01 RES 374K OHM 1 8 W 1 0805 Panasonic P374KCCT ND Panasonic ERJ 6ENF3743V R02 R03 RES ZERO OHM JUMPER 2 A 1206 Vishay 541 0 0ECT ND Vishay CRCW 12060000Z0EC R04 N A N A N A N A N A R05 RES 23 7 OHM 1 8 W 1 0805 Panasonic P23 7CCT ND Panasonic ERJ 6ENF23R7V R08 RES 0 OHM JUMPER 1 A 0603 Panasonic P0 0GCT ND Panasonic ERJ 3GEY0R00V R10 N A N A N A N A N A R11 RES 20 OHM 1 4 W 1 1206 Panasonic ...

Страница 6: ...The Power Behind Performance Rev 1 0 07 14 vicorpower com Applications Engineering 800 927 9474 Page 6 Figure 2 HDC Customer Evaluation Board Schematic ...