background image

19 | VWG-50-Installation Manual 

 

C

ERTIFICATIONS 

 

 

Federal Communications Commission (FCC) 

This equipment generates, uses, and radiates radio frequency energy, and if not installed 
and used in accordance with the instruction manual, may cause interference with radio 
communications. It has been tested and found to comply with the limits for a computing 
device pursuant to Part 15 Subpart C of FCC Rules, which are designed to provide 
reasonable protection against such interference when operated in a commercial 
environment.  

 

Canadian Department of Communications (ICES-003) 

This digital apparatus meets all requirements of the Canadian Interference-Causing 
Equipment Regulations. 

Cet appareil numérique respecte toutes les exigences du Règlement sur le matériel 
brouilleur du Canada. 

 

S

PECIFICATIONS 

 

 

Platform 

• PowerPC 405EP 250 MHz processor 
• 64MB SDRAM & 64 MB Serial Flash 
• 128 KB Static RAM 
• Battery Backup - 5 minutes typical - shutdown begins within 10 seconds 
• Real-time clock - 3 months backup max via battery 

 

Operating System 

• QNX RTOS 
• IBM J9 JVM Java Virtual Machine 
• NiagaraAX 
 

Wired Communications 

• 2 Ethernet Ports – 10/100 Mbps (RJ-45 Connectors) 
• 1 RS 232 Port (9 pin D-shell connector) 
• 1 RS 485 non-isolated port (3 Screw Connector on base board) 
 

Wireless Communications 

• Direct spread spectrum 2.4 GHz ISM bands 
• Transmission power is under 1 mW at –0.4 dBm for channels 11 to 25 and –4.0 dBm for 
channel 26 
 

Power Supply 

• VWG-PS-AC 120 VAC to 15 VDC power supply for VWG with cord 
 
 
 
 

Содержание VWG-50-5000

Страница 1: ...ring Details 10 Grounding 10 VWG PS AC 120 VAC Wall mounted power supply 11 Power Wiring 11 Communications Wiring 11 Ethernet BACnet over IP wiring 11 RS485 BACnet MS TP wiring 13 Antenna installation...

Страница 2: ...Viconics wireless gateway All Viconics wireless gateways and related wireless controllers are to be used only as operating controls Whenever a control failure could lead to personal injury and or loss...

Страница 3: ...D INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION TRADEMARKS Niagara Niagara AX is a registered trademark of Tridium Inc LON LonWorks and LonTalk are registered trademarks of Echelon Corpora...

Страница 4: ...the VWG PREPARATION Unpack the VWG and power module either VWG PS DC or VWG PS AC and inspect the contents of the packages for damaged or missing components Be sure the factory installed ferrite is on...

Страница 5: ...omething that can result in personal injury or equipment damage Warnings contain an explanation of why the action is potentially dangerous Safety Precautions The following items are warnings of a gene...

Страница 6: ...ischarge Follow these precautions when installing servicing or operating the system Work in a static free area Discharge any static electricity you may have accumulated Discharge static electricity by...

Страница 7: ...enclosure with other heat producing equipment Do not mount the unit In an area where excessive moisture corrosive fumes or explosive vapors are present Where vibration or shock is likely to occur In a...

Страница 8: ...ith clips provided by the DIN rail vendor or place a screw in one of the four mounting tabs in the base of the VWG Removing and Replacing the Cover You must remove the VWG cover to connect the battery...

Страница 9: ...VWG 50 Installation Manual Installation Minimum Spacing Distance Requirements Make sure minimum spacing distance requirements is available to freely rotate wireless antenna in all possible orientation...

Страница 10: ...tional details 4 Connect the backup battery to the VWG battery connector and apply power to the unit See Power Up and Initial Checkout page 17 Grounding Use an earth ground spade lug 0 187 on the base...

Страница 11: ...pply into the VWG until all other mounting and wiring is completed See Power Up and Initial Checkout section Communications Wiring Connect communications wiring to the VWG using Net1 Net2 or the RS 48...

Страница 12: ...rmation for details on the default IP address and how to change it The supplied ferrite in the VWG packaging needs to be installed on the IP wire in a specific way for FCC compliance Place IP wire int...

Страница 13: ...to the TIA EIA 485 standard The screw terminals from left to right are shield plus and minus The supplied ferrite in the VWG packaging needs to be installed on the MS TP wire in a specific way for FC...

Страница 14: ...ed when the controller is installed inside a closed metal enclosure Gently screw the female connection of the remote antenna into the VWG Remote antenna has a weighted magnetic base for metal surface...

Страница 15: ...ery pack mounted to the unit under the cover This battery allows the VWG to continue operation through very short power bumps a few seconds in duration If a longer power outage occurs the battery prov...

Страница 16: ...that port as follows Off No Ethernet link is made On Ethernet link is present but no activity on the LAN Blinking Ethernet link is present with data activity on the LAN Beat The BEAT LED is located t...

Страница 17: ...gent 2 Required Battery Maintenance Battery life expectancy is a function of its discharge cycles the number of discharges and their depth and the ambient temperature of the battery during normal oper...

Страница 18: ...ftware configuration and is not a field upgrade For additional information if modifying the memory capacity of the VWG contact Viconics for technical support Fuse The VWG contains a non user replaceab...

Страница 19: ...erference Causing Equipment Regulations Cet appareil num rique respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada SPECIFICATIONS Platform PowerPC 405EP 250 MHz processor 6...

Страница 20: ...ature range 0 to 60 C 32 F to 140 F Relative humidity range 5 to 95 non condensing Agency Listings UL 916 C UL listed to Canadian Standards Association CSA C22 2 No 205 M1983 Signal Equipment FCC Part...

Отзывы: