TABLE 1: ORDER CODE                                              

H200

-

A-B

-

C-D

-

E-F

A

Output no. 1 ( controlled device )

1

ON/OFF (15 min. time base)

4

(PWM) 24 VAC

5

(PWM) 5 VDC

6

Analog 0-10 VDC

B

Output no. 2 ( controlled device )

0

Not installed

1

ON/OFF (15 min. time based)

4

(PWM) 24 Volts AC

5

(PWM) 5 Volts DC

6

Analog 0-10 Volts DC

8

Signal transmitter 0-10 VDC
(1V= 10% , 9V-90%)

9

Signal transmitter 0-5 VDC
(0.5V= 10% ; 4.5 V=90%)

C

Output no. 1 and 2 control mode

1

Humidify

2

Dehumidify

3

Humidify ( no. 1 ) and dehumidify ( no. 2 )

4

Dehumidify ( no. 1 ) and humidify ( no. 2 )

D

Main sensor location

Sensor

0

Not installed

None

1

Inside humidistat ( Local )

H50

2

Duct mount ( stat on duct )

H60

3

Duct mount ( stat on wall )

H71

4

Remote wall mount

H80

E

Setpoint adjustment

1

User adjustable

2

Blind cover

F

Future option

0

Unused

Example:  H200 - 61 - 32 – 10
One “SCR” 0 to 10 volts humidify output and one relay
dehumidify output.
Humidistat and sensor are duct mount. Setpoint is user
adjustable.

   Resolution:  0.5 %  for retransmit only

 See sensor specifications for dimensions of sensors

Note: the complete  order code includes the sensor that will
be shipped with the humidistat.

WIRING                                                                         

2 ON/OFF OUTPUTS

Single transformer

Fig.2: Wiring diagram with single transformer

Multiple transformers

Fig.3: Wiring diagram with multiple transformers

Note:  Both of the above wiring diagrams show how to
wire output of type 1, 2, 3 and 4 (switched 24 Vac).
For outputs of type 5 and 6 (Vdc out) refer to Fig.4 and
Fig.5 on next page.

BLACK

COMMON

6

10

8
9

7

+10 Vdc

MAIN SENSOR

N/A

N/A

INPUT

HUMIDITY SENSOR

FOR CONTROL

RED

WHITE

4

5

1

3

2

OUTPUT #1

ON / OFF

24 Vac

OUTPUT #2

ON / OFF

24 Vac

24 Vac

24 Vac

+

or 24 Vac VALVE

RELAY

-

or 24 Vac VALVE

+

RELAY

-

BLACK

COMMON

6

10

8
9

7

+10 Vdc

MAIN SENSOR

N/A

N/A

INPUT

FOR CONTROL

HUMIDITY SENSOR

WHITE

RED

4

5

1

3

2

OUTPUT #1

ON / OFF

24 Vac

OUTPUT #2

ON / OFF

24 Vac

+

or 24 Vac VALVE

RELAY

-

or 24 Vac VALVE

+

RELAY

-

Содержание Micro-stat H200 Series

Страница 1: ...page 5 for location Each humidistat is computer calibrated and factory programmed with default parameters All control parameters such as proportional band stage differential etc may be changed in the field with the H263 programming tool without having to remove the thermostat cover The H263 also doubles as a diagnostic tool and indicates the status of all the inputs and outputs and will reduce tro...

Страница 2: ...y output and one relay dehumidify output Humidistat and sensor are duct mount Setpoint is user adjustable Resolution 0 5 for retransmit only See sensor specifications for dimensions of sensors Note the complete order code includes the sensor that will be shipped with the humidistat WIRING 2 ON OFF OUTPUTS Single transformer Fig 2 Wiring diagram with single transformer Multiple transformers Fig 3 W...

Страница 3: ...o output 2 The humidity sensor is located in the return air duct Humidistat model number H200 69 13 10 Fig 6 Application example 6 COMMON N A INPUT MAIN SENSOR N A 10 Vdc 9 10 8 7 OUTPUT 1 TRANSMITTER 0 to 10 Vdc 0 to 5 Vdc OUTPUT 2 24 Vac 0 to 10 Vdc 4 5 3 24 Vac 2 1 FOR CONTROL HUMIDITY SENSOR RED BLACK WHITE DDC SYSTEM ELECTRONIC MOTOR or SCR or METER 6 COMMON N A N A INPUT MAIN SENSOR 10 Vdc 9...

Страница 4: ...uct mounted humidistat This humidity sensor can be mounted directly onto the supply or return of the ventilation duct The H200 may be located on the wall with humidity sensing from the remote H71 sensor location H80 REMOTE WALL SENSOR H263 PROGRAMMING TOOL This humidity sensor can be wall mounted in any remote location The humidistat may be located on the duct or other location with humidity sensi...

Страница 5: ...ol Code t1 0 On off 1 8 minutes 2 1 second Time 1 Time period for output no 1 t2 0 On off 1 8 minutes 2 1 second Time 2 Time period for output no 2 rA 0 C 1 F 1 DO NOT CHANGE Range Temperature Scale Ca 13 Calibration deviation mode DO NOT MODIFY USE AUTOCAL PROCEDURE FOR H100 TRANSMITTER USE THE ZERO POTENTIOMETER ON THE TRANSMITTER hA 0 à 127 Hardware assembly Code related to thermostat model and...

Страница 6: ... 5 C to 50 C 32 F to 122 F Control 0 to 95 R H non condensing Sensor 0 to 100 R H see Note 1 Resolution 0 1 Repeatability 0 5 Accuracy and sensor interchangeability 2 R H from 0 to 100 R H Range 10 to 90 R H for 5 to 50 C 41 F to 122 F Temperature effect 0 05 F Outputs Isolated Triac 30 Vac at A max 0 to 5 VDC into 1KΩ resistance min 0 to 10 VDC into 2KΩ resistance min 0 5 VDC at 20 mA max for bot...

Отзывы: