background image

 

 
 
 

 

 
 
 

Vicon Industries Inc.

 

 
 

Corporate Headquarters 

89 Arkay Drive 

Hauppauge, New York 11788 

631-952-CCTV (2288)    800-645-9116 

Fax: 631-951-CCTV (2288) 

!

Infofax:  800-287-1207 

 
 

Vicon Europe 
Headquarters 

Brunel Way 

Fareham, PO15 5TX 

United Kingdom 

44/(0)  1489/566300 

Fax: 44/(0)  1489/566322 

 
 

Brussels Office 

Planet II - Unit E 

Leuvensesteenweg 542 

B-1930 Zaventem 

Belgium 

322 712 8780 

Fax: 322 712 8781 

 
 

Far East Office 

Unit 5, 17/F, Metropole Square 

8 On Yiu Street, Shatin 

New Territories, 

Hong Kong 

(852) 2145-7118 

Fax: (852) 2145-7117 

 
 
 

Internet Address: www.vicon-cctv.com

 

 

Содержание V900-2.8HB-24

Страница 1: ...has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2001 Vicon Industries Inc All rights reserved Product specifications subject to change with...

Страница 2: ......

Страница 3: ...pection for Concealed Damage 2 Roughneck V900 Dome Components 2 Mounting the Unit 3 Cable Connections 4 Coaxial Video Cable 5 Camera Power Connections 6 Heater Connections 7 Camera Synchronization 7 C...

Страница 4: ...tion For experienced installers use the installation diagram below Figure 1A for indoor versions and Figure 1B for outdoor versions For complete detailed instructions on how to install the V900 read t...

Страница 5: ...X986 03 02 Rev 1001 Roughneck V900 Dome Cameras Quick Installation iii Figure 1B Installation Diagram Exploded View Outdoor Version...

Страница 6: ......

Страница 7: ...gh resolution monochrome or color with a choice of lenses Both monochrome and color cameras accept 24 VAC or 24 VDC while color cameras also feature line lock capability If varifocal lens models are s...

Страница 8: ...bly and a cover with a clear dome some models include a mask Some units are delivered completely assembled others require lens installation Refer to Figure 1 Base Camera Mounting Bracket The base of t...

Страница 9: ...4 Optional Step If it is desirable to convert the threaded port DIN 40430 Pg 11 for the liquid tight fitting to a 1 2 inch NPT an adapter is needed Pg11 to 1 2 in NPT This adapter is commercially ava...

Страница 10: ...ts the wall or ceiling Figure 2 Mounting Hole Pattern Figure 3 Installation of NPT Adapter Cable Connections Both power and video connections are made to the printed circuit board PC board mounted to...

Страница 11: ...tor on the pendant cable on the PC board As an alternative there is a special video connector on the PC board Refer to Figure 4A and 4B 1 Strip the video cable insulation to expose the ground Refer to...

Страница 12: ...oping Ground loops only occur on multiple camera installations where a difference of ground potential exists between cameras causing a base frequency 50 Hz 60 Hz distortion on the video signal It affe...

Страница 13: ...in a line lock video application high resolution color cameras only the camera interface board is already set in line lock mode by default The use of line locking synchronization using a V phase poten...

Страница 14: ...switches 4 5 and 6 control shutter speed when switch 7 is set ON Low AGC and BLC can be set Backlight control BLC and automatic gain control AGC ON OFF are DIP switch selectable on this color camera...

Страница 15: ...Installation After all cable connections are made test the camera lens to see if any further adjustments are necessary When the camera and lens adjustments are complete replace the foam mask over the...

Страница 16: ...alignment of holes and screws is acceptable The cover can be rotated 90 by aligning the screws holes differently Caution For moisture protection Vicon recommends that when the cover is reattached it...

Страница 17: ...r they should be removed with clean dry air pressure compressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl alcohol and wa...

Страница 18: ...tries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information...

Страница 19: ...bject to moisture The shield must be copper braid providing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely...

Страница 20: ......

Страница 21: ...00 305 1600 488 2500 762 24 VDC 280 85 438 134 700 213 1120 341 1750 533 Heat Equivalent 0 7 btu min 0 19 kg cal min without heaters 1 7 btu min 0 43 kg cal min with heaters Note These figures represe...

Страница 22: ...e Diameter 3 5 in 89 mm Weight Approximately 4 lb 1 8 kg Construction Indoor Base Cover sand cast aluminum Outdoor Base Cover permanent mold cast aluminum Dome polycarbonate plastic Finish Base Cover...

Страница 23: ...100 000 linear or 1 60 1 100 1 250 1 500 1 1000 1 2000 1 400 1 10 000 selectable On Off selectable On Off selectable 48 dB AGC off V900358HC 24 V900 358HC 24C 1 3 CCD 2 1 interlace NTSC PAL Color 460...

Страница 24: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712...

Отзывы: