background image

<DAY/NIGHT AUTO MODE> 
 
 
 
 
 
 
 
 
 
 
 
<DAY/NIGHT B/W MODE> 
 
 

3DNR (Digital Noise Reduction) 

You can configure the DNR(Digital Noise Reduction) related settings.  
If you press the Setup switch when ON is selected in 3DNR, the corresponding 
screen appears. 

 
 
 
 
 
 
 
 
 
 
 
 
 

SPECIAL 

1) CAM TITLE

 

 

A. CAM TITLE 
B. Character Table 
C. Command Line 
     

Å

  :  Move to left 

     

Æ

  :  Move to right 

    CLR :  Erase all characters 
    POS :  Move the position of title 
    END :  Save and End 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

15

Содержание V660B-312IR

Страница 1: ...ly as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc 89 Arkay Drive Hauppauge New York 11788 Tel 631 952 2288 Fax 631 951 2288 Toll Free 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 Document Number 8009 8230 00 01 Product specifications subject...

Страница 2: ...ant operating and maintenance servicing instructions in the literature accompanying the product PRECAUTIONS Safety Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it any further Unplug the unit from the wall outlet if it is not going to be used for several days or more To disconnect the cord pull it out by the plug...

Страница 3: ...MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DI...

Страница 4: ...m being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from t...

Страница 5: ...E OF CONTENTS INTRODUCTION 6 PACKAGE CONTENTS 7 DIMENSIONS 7 WATER INGRESS PREVENTION 7 BASE INSTALLATION 8 CAMERA CONNECTIONS 8 STRUCTURE OF THE SETUP MENU 10 THE DEFINITION OF TERMS 11 SPECIFICATIONS 18 5 ...

Страница 6: ...Function Digital Wide Dynamic Range Function BLC Back Light Compensation Function AGC Auto Gain Control Function Motion Detection Function IR Range distance up to 40M Color B W auto switch by photo TR Operates in 12V DC 24V AC Cable thru bracket Weatherproof housing IP 66 Camera Mount Camera mount directly to the wall or ceiling RS 485 Remote camera control Fastrax Pelco D and P IMPORTANT The user...

Страница 7: ...ontrol Zoom Focus ring and unscrew remote control port Screw Firmly attach the bracket to the wall or ceiling DIMENSIONS WATER INGRESS PREVENTION After using the REMOTE CONTROL and lock completely the REMOTE CONTROL PORT CAP Caution This is a sealed camera with no internal adjustments and as such opening the case may invalidate the warranty 7 ...

Страница 8: ...ow to Adjust ZOOM FOCUS Remote Controller Insert the din jack of remote controller to the hall of housing Adjust the zoom using up down key Adjust the focus using left right key Keyboard Controller Connect the 485 of Keyboard controller with 485 Terminal Block Adjust the zoom using the tele wide key Adjust the focus using the near far key 8 ...

Страница 9: ...her etc 2 RS 485 2 pin terminal block used to connect to keypads controllers etc Green wire is RS 485 Blue wire is RS 485 3 Power 3 pin terminal block used for 24 VAC 12 VDC power connection Autosenses polarity 4 Motion 2 pin terminal block used for motion output Yellow wire is motion out Black wire is ground 9 ...

Страница 10: ... 8 RESET 9 EXIT LENS DC EXPOSURE SHUTTER BRIGHTNESS AGC SENSE UP BLC D WDR RETURN WHITE BAL AWB AWC SET MANUAL INDOOR OUTDOOR ATW DAY NIGHT AUTO EXT B W COLOR 3DNR LEVEL RETURN SPECIAL CAM TITLE D EFFECT RS485 MOTION PRIVACY SYNC LANGUAGE RETURN ADJUST SHARPNESS BLUE RED RETURN RESET FACTORY RETURN 10 ...

Страница 11: ...ensates for the brightness of the subjects with a large amount of background light that would make it practically impossible to see any details of the subjects Adjusts the iris so that a distinctive subject and the background are delivered at the same time Wide Dynamic Range WDR Extends the action of BLC When both high brightness subjects and low brightness subjects are in the same scene overexpos...

Страница 12: ...nchronized to prevent picture roll when switching between cameras in multiple camera installations White Pixel Automatically detects and compensates for peak white levels to maintain the image quality White pixels whose frequency of occurrence varies in proportion to the temperature are sometimes observed when the devices are used under the influence of external factors or especially high temperat...

Страница 13: ... level of brightness for the user can be achieved by adjustment EXPOSURE The EXPOSURE menu is used to set the automatic light control method for this camera 1 SHUTTER Select the shutter mode 1 60 50 FLK 1 100 000 sec x2 x256 Can be changed while in shutter mode 2 BRIGHTNESS Adjust BRIGHTNESS level 0 100 Can be adjusted while in manual lens mode 3 AGC Auto gain control OFF LOW MIDDLE HIGH 4 SENSE U...

Страница 14: ...onment including the light source is changed you have to adjust the while balance again 3 MANUAL Manual mode User can change R and B Gain manually 4 INDOOR Set the color temperature to 3200 K 5 OUTDOOR Set the color temperature to 6300 K 6 ATW Set the color temperature 2500 K to 9500 K WHITE BAL MANUAL MODE DAY NIGHT The DAY NIGHT menu is used to configure the day and night related setting for thi...

Страница 15: ...ital Noise Reduction related settings If you press the Setup switch when ON is selected in 3DNR the corresponding screen appears SPECIAL 1 CAM TITLE A CAM TITLE B Character Table C Command Line Å Move to left Æ Move to right CLR Erase all characters POS Move the position of title END Save and End 15 ...

Страница 16: ...38400 PROTOCOL Select RS485 protocol FASTRAXⅡ PELCO D PELCO P 4 MOTION AREA SELECT Select MD area number AREA DISPLAY Select MD ON OFF LEFT RIGHT Adjust the location of the MD area with boundary LEFT and RIGHT WIDTH Adjust width of MD area TOP BOTTOM Adjust the location of the MD area with boundary TOP and BOTTOM HEIGHT Adjust height of MD area SENSITIVITY Adjust sensitivity of MD area 0 40 DURATI...

Страница 17: ...ct Internal or Line Lock mode INT This mode is necessary for using the internal synchronization L L This mode is necessary for the operation of multi camera because it synchronizes the camera phase by using the external signal AC Signal PHASE Sync phase is adjustable in line lock mode 7 LANGUAGE You can change the OSD language using the LEFT RIGHT Setup ADJUST 1 SHARPNESS Can be adjusted SHARPNESS...

Страница 18: ...e control RS485 D WDR On Indoor Outdoor Off BLC BLC HSBLC OFF Day Night Color BW Auto SENSE UP Auto x2 x128 PM 0 8 Zone WB AWB AWC Manual Indoor Outdoor ATW AGC On Low Middle High Off Exposure Auto MI EI Manual Shutter Flickerless Shutter Speed Normal 1 100 000 Brightness 0 100 Steps Sharpness 0 31 Steps Camera ID 0 255 Title A Z 0 9 Flip Horizontal Vertical Rotate Effect D Zoom x32 Pan Tilt Nega ...

Страница 19: ...h policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall...

Страница 20: ...dquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon security com 50302971D ...