2. Remove the pan limit-stops by pulling them
outward. The pan limit-stops are located
in the series of radial slots around the
base.
ACTUATOR
LEVER
PAN LIMIT STOPS
SQUARE BASE VERSION
PAN LIMIT STOPS
WALL MOUNT VERSION
Figure 4
Limit Switch Actuator and Pan Limit Stops
3. Press the joystick to pan to the desired
limit of right
An actuator lever extends down from the
pan-and-tilt head in the
area
between the head
and the wall mount, viewed from the rear of
the camera. The location is similar to that
shown in Figure 4.
4. Press the limit-stop into the slot just to
the left of the actuator lever.
NOTE: Limit-stop selection is made in
lo-degree increments.
5. Press the joystick to pan to the desired
limit of left rotation.
6. Press the limit-stop into the slot just to
the right of the actuator lever.
7. Pan to each limit to check for exact trim.
This completes the installation and adjustment
of the unit.
OPERATION
The pan, tilt, and
functions of the
and
are controlled
remotely with a suitable pan-and-tilt control.
NOTE: If the operator continues to press the
pan-and-tilt control after the unit has
reached a
pan
limit-stop, a slight vibration
will be observed on the monitor screen. This
does not harm the unit, but Vicon recommends
that pressure on the control be released once
the limit-stop has been reached.
MAINTENANCE
Under normal operating conditions, the
and
require no
maintenance.
Always check external equip-
ment, cables, and connectors before trouble-
shooting. See Wiring Diagram and Parts
Location Diagram, Figures 5 and 8, and the
Replacement Parts List.
x573-492