2
••
Installation
X672 Rev 700 V200VA-B
Location
The video amplifier should be located at the monitor end of the video system. It is not necessary, however, that
the amplifier be located immediately adjacent to the monitor. Refer to Table 1 for maximum operating distances
between the camera and the V200VA-B.
Table 1
Maximum Distance Between Camera and V200VA-B
Cable Size
Maximum Distance
RG-11/U
6500 ft (2000 m)
RG-6/U
4800 ft (1500 m)
RG-59/U
3400 ft (1000 m)
Adjustment Connection
1. Connect the video cable from the output of a camera, switcher, or other video device to the connector
marked CAMERA on the rear panel of the V200VA-B. See Figure 1.
2. Connect a video cable from the connector marked MONITOR on the rear panel of the V200VA-B to the input
of a monitor, switcher, or other video device with 75-ohm termination. If several devices are wired in a looping
arrangement, the last one in the chain must be terminated by 75 ohm impedance.
Figure 1
Front and Rear Panels