36
•
Camera and Monitor Connection
Pilot Ultra XX189-00-XX
Looping Monitor Outputs
In multiple cage configurations, the Video Amplifier Board installed in the Primary cage, must be looped to the
RS422 to CMOS Converter card installed in the Secondary Cage, so that the cameras connected to the
Secondary cage will be viewable on the monitors connected to Primary cage. This is accomplished by
connecting the D-shell connectors on the monitor BNC cards in the Primary and Secondary cages using the
V1566RC-36 coaxial cables as shown in Figure 32. Note that the D-shell connectors are assigned to specific
BNC connectors. The connector on the left is assigned to the odd numbered terminals. The connector on the
right is assigned to the even number terminals.
Figure 32: Looping Primary and Secondary Cage Monitor BNC Panels