Vicon SurveyorVFT Скачать руководство пользователя страница 18

Preset 97 (Initiate Dome Reset)

 — Storing preset 97 resets all of the system software and performs the 

power-on self-test. This is called a “soft reset” because no memory settings are affected. All user 
programmed options such as titles and presets remain unchanged. Recalling preset 97 has no effect. 

Preset 98 (Programming Autopan Limits)

 — When a SurveyorVFT is selected on a keyboard, pressing 

the 

AP

 (autopan) key will start the camera in motion, panning at a predetermined speed. 

 

To change the speed 

— Press and hold the 

AP

 key while moving the joystick to the desired speed. 

When the speed is correct, release the 

AP

 button and then the joystick. Each dome may have its 

own autopan speed and pressing the autopan key will start the dome panning at the last speed 
selected for that dome. (When using a Kollector DVR, shut off AP, move the slider to desired speed 
and press AP again.) In continuous rotation only,  the autopan command will cause the dome to 
reverse direction. 

 

To stop autopanning

 — Any other pan command will disable autopan. This includes pressing the 

AP

 key again, panning the camera with the joystick, or recalling a preset. 

 

To set the autopan limits

 — When a continuous rotation dome is in autopan, it will rotate in a full 

circle until autopan is disabled. When an application, such as a wall-mounted camera on a building, 
does not require continuous rotation, limits are set to define the left and right boundaries. Storing 
preset 98 will bring up a series of prompts to set the left and right autopan limits with the AUX 2 and 
AUX 3 keys. When the autopan limits are set and the camera is placed into autopan it will pan until 
it reaches a limit. It will then reverse direction until it reaches the opposite limit, repeating this cycle 
indefinitely. 

To clear the autopan limits — 

Store preset 98. Press AUX 2 and AUX 3 without panning to set the 

autopan limits to the same position. By recording both limits on the same point they will both be deleted. 
The dome will now rotate continuously when placed in autopan mode until new limits are programmed. 
Recalling presets 98 has no effect. 

Preset 99 (Set Manual Pan Limits)

 — Storing preset 99 will bring up a series of prompts to set the left 

and right manual pan limits with the AUX 2 and AUX 3 keys. After these are set, the physical range 
between these limits is the valid range. The camera dome will not move outside these limits. Setting pan 
limits also sets AP limits if the AP limits are outside the of the pan limits. The only exceptions are 
prerecorded tours and previously stored presets. To clear the pan limits, press AUX 2 and AUX 3 without 
panning. 

Programming Menus 

The Main Programming Menu is the first one seen when entering 
programming mode (store preset 94). Subsequent menus, called sub-
menus, are accessible from this point. When in programming mode, a 
function is entered by pressing the 

AP

 (autopan) key. To back out of that 

function without changes, press the 

AI

 (autoiris) key. Instructions are 

available on the screen for almost all functions. Since many of the 

menus available on the SurveyorVFT are similar, not all are shown here. For convenience, 
press the L-SPD (lens speed) button to display a black background. 

The selections available on this menu can be summarized as follows: 

System Settings —

 Allows the user to adjust the speed of the pan and tilt axes. Solving preset 

positions is always done at full speed. This menu also controls the Zoom Scalable Pan/Tilt, 
Compass, PTZ Timeout, Address Setting, Flip, Fan Speed, and Privacy Mask Zoom Level 
features (Frame Noise Reduction and CCD mode on certain models). 

Camera Controller —

 Permits user adjustment of the advanced video features available on the 

SurveyorVFT

.

 

Содержание SurveyorVFT

Страница 1: ...your requirements or that the operation will be entirely error free or perform precisely as described in the documentation This system has not been designed to be used in life critical situations and...

Страница 2: ...onal Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrod...

Страница 3: ...series includes 23X and 36X models 2 Standard PTZ SurveyorVFT Indoor Pendant SVFT P series includes 23X and 36X models 3 Standard PTZ SurveyorVFT Outdoor Pendant SVFT W series includes 23X and 36X mo...

Страница 4: ...Quick Installation Standard PTZ In Ceiling Model...

Страница 5: ...Quick Installation Standard PTZ Indoor Pendant...

Страница 6: ...Quick Installation Standard PTZ Outdoor Pendant...

Страница 7: ...Quick Installation SVFT M Impact Resistant...

Страница 8: ...Quick Installation SVFT PRS Pressurized Pressurize the housing with Dry Nitrogen gas according to the procedure in this manual Reinstall cap on fill valve Reinstall service cover...

Страница 9: ...Quick Installation Fixed In Ceiling Access to Ceiling...

Страница 10: ...Quick Installation Fixed In Ceiling No Access to Ceiling...

Страница 11: ...Quick Installation Fixed Indoor Pendant...

Страница 12: ...Quick Installation Fixed Outdoor Pendant...

Страница 13: ...rveyorVFT and SVFT M J2 for optional fiber optics interface board that provides video and RS 422 full duplex data through a standard fiber optics connector Wiring Connections Standard Coaxial Fiber Op...

Страница 14: ...ns ViconNet Version Pin Connections SVFT PRS Prefabricated cable On coaxial and UTP units L M X and U are not used On fiber units L M J K X and U are not used On ViconNet units A C D P T L M J K X and...

Страница 15: ...video an ST connector for fiber optic or an RJ 45 connector on the ViconNet board for video connection and a removable two position screw terminal connector for camera power DIP Switch Settings The ad...

Страница 16: ...sectors 97 Initiate Dome reset 98 Autopan limits 99 Set manual pan limits Presets are usually solved at the maximum speed typically less than 1 second if a preset is assigned to a tour or salvo the p...

Страница 17: ...Auto baud detect functions after installing defaults using preset 95 when switching Vicoax to Pilot NOVA VPS and upon power up when the dome sees an incorrect baud rate from keypad or control system I...

Страница 18: ...le indefinitely To clear the autopan limits Store preset 98 Press AUX 2 and AUX 3 without panning to set the autopan limits to the same position By recording both limits on the same point they will bo...

Страница 19: ...mera dependent those are not listed Note On unit power up when DIP switch SW2 positions 2 6 7 and 8 are all set to ON the unit will perform an Install Defaults Pressurization Pressurizing the Housing...

Страница 20: ...an 2 psi per year Note The housing with mechanism has approximately 490 in 3 of volume Note The pressurized function has not been evaluated by UL Warning Do not use any gas type other than dry Nitroge...

Страница 21: ...ature applications in that it directs warm air onto the lower bubble surface minimizing icing and foggingIcondensation problems Its installation is shown pictorially in the figures below The duct snap...

Страница 22: ...1 minimum is required to be able to access this mode which should be installed in conjunction with installing the duct This firmware enables you to run the heater fan at max speed at low temperature...

Страница 23: ...been authorized for return by the Company and the return shipment is prepaid in accordance with policy Repaired or replacement hardware will be warranted for the remainder of the original Warranty Per...

Страница 24: ...all not exceed the price paid for the product These limitations on potential liabilities have been an essential condition in setting the product No one is authorized to assume any liability on behalf...

Страница 25: ...Vicon Industries Inc For office locations visit the website www vicon security com...

Отзывы: