Quick Guide

Programming

For detailed instructions, see Surveyor2000 Programming Manual.

Programming Steps Performed with the Control Device Only

Note: Refer to V1300X-DVC and V1300X-RVC Intelligent Remote Control Panels Instruction Manual X777 and/or

V1400X-DVC System Console Instruction Manual X923 for operations, depending on the control device being used.

Storing Presets:  

A preset is a pre-programmed camera position.

Presets may be created either directly from the control device or through the programming menus. Since the control

device method is usually used, it is shown here:

Select a monitor.

Move camera to

desired position.

Select a camera.

Enter desired

preset number.

Deflect the joystick in either 

horizontal direction until desired pan 

speed is attained. Hold in place.

Press and hold the 

autopan key.

Release the 

autopan key.

Release 

joystick.

Programming Autopan Speed:  

Sets a constant pan speed for autopan operation.

Programming Sectors:  

A sector is a specific portion of the 360˚ viewing area.

Pan the selected 

camera to left 

end of sector 1.

Enter preset “96”. 

This defines the left 

end of sector 1.

Pan to the 

right end of 

sector 1.

Pan to the 

right end 

of sector 2.

Press the autopan key. This defines the 

right end of sector 1, the left end of sector 

2 and displays the title of sector 2.

Press the autopan key. This defines the 

right end of sector 2, the left end of sector 

3 and displays the title of sector 3.

Repeat the “pan right-press A/P” steps for all desired 

sectors (the maximum is 16). At the last desired sector, 

hold joystick to the right until the unit stops.

When finished press the autopan 

key until the title of sector 1 is 

displayed again.

Programming Autopan Limit Stops:  

Limit stops control how far the Surveyor2000 can pan.

Pan the camera to 

the left end of the 

autopan sector.

Pan the camera to 

the right end of the 

autopan sector.

Enter preset “98”.

Enter preset “99”.

Enter preset “98”.

Enter preset “99”.

Programming Continuous Rotation Panning:  

Removes the pre-programmed limit stops.

Vicon Industries Inc. 89 Arkay Drive, Hauppauge, NY 11788

2

1

1

6

1

2

1

2

1

2

3

4

3

4

7

8

2

3

4

5

2

3

4

Содержание Surveyor2000

Страница 1: ...ms Camera Dome System ZOOM IN IRIS OPEN ZOOM OUT FOCUS FAR FOCUS NEAR IRIS CLOSE RUN PGM Quick Guide This Vicon Quick Guide is intended to get you up and running quickly See the complete manuals for in depth information on the Surveyor2000 1 ...

Страница 2: ...s A sector is a specific portion of the 360 viewing area Pan the selected camera to left end of sector 1 Enter preset 96 This defines the left end of sector 1 Pan to the right end of sector 1 Pan to the right end of sector 2 Press the autopan key This defines the right end of sector 1 the left end of sector 2 and displays the title of sector 2 Press the autopan key This defines the right end of se...

Страница 3: ...rol device s joystick or the autopan key to make a menu selection Use the autoiris button to exit the menu Select a monitor Select a camera Enter preset 94 Pan Tilt Controller Adjust max pan tilt speeds and enable disable the zoom scalable pan tilt feature Camera Controller Adjust autoiris autofocus shutter speed and V phase Alarm Handling Enable alarms and reports define alarm status acknowledgem...

Страница 4: ...mera Enter preset 88 or 89 Enter auxiliary number 1 Storing an Autotour Select a monitor Move camera to desired starting position Pan tilt and zoom to each step in the autotour Refer to the manual for details Enter auxiliary number 1 Press the autopan key to save autotour Deflect joystick up down to move to extra settings using right left to define NO ACTION Nothing happens PRESET Recalls preset A...

Страница 5: ...ddress and communications mode The control of my Surveyor2000 is intermittent What is wrong Check the data connections on the Surveyor2000 and on any other units linked to it through the Ro and Cin connections What address should I use for my Surveyor2000 Use the number of the physical connection of the Surveyor2000 to the control system or matrix switcher Define this number to the Surveyor2000 us...

Отзывы: