background image

XX077-00-00 Rev 1201 Surveyor2000-MSH Maximum Security Housing 

Shipping Instructions  

••••

  9 

Shipping Instructions 

Use the following procedure when returning a unit to the factory: 
 

1.  Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name 

of the Vicon employee who issued the R.A. 

 

Vicon Industries Inc. 
89 Arkay Drive 
Hauppauge, NY  11788 
Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) 

 

For service or returns from countries in Europe, contact: 

 

Vicon Europe Ltd 
Brunel Way 
Fareham, PO15 5TX 
United Kingdom 
Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322 

 

2. 

Attach a sheet of paper to the unit with the following information: 

 

a. 

Name and address of the company returning the unit 

b. 

Name of the Vicon employee who issued the R.A. 

c. R. 

A. 

number 

d. 

Brief description of the installation 

e. 

Complete description of the problem and circumstances under which it occurs 

f. 

Unit’s original date of purchase, if still under warranty 

 

3.  Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 

4.  Mark the R.A. number on the outside of the carton on the shipping label. 

Содержание Surveyor 2000-MSH

Страница 1: ...stem has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2001 Vicon Industries Inc All rights reserved Product specifications subject to change...

Страница 2: ......

Страница 3: ...rveyor2000 MSH Maximum Security Housing Components 3 Unpacking and Inspection 3 Accessory Kit 3 INSTALLATION 6 Mounting the Unit 6 OPERATION 8 MAINTENANCE 8 Care and Cleaning of Clear Acrylic Domes 8...

Страница 4: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Quick Installation 2 Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N...

Страница 5: ...ing Components The MSH consists of a thick steel Enclosure a sealed Lower Dome assembly and mounting studs for the Surveyor2000 Camera Drive In addition the Housing provides outside holes for external...

Страница 6: ...615 00 1 4 in monochrome camera EIA version 22x zoom high resolution camera lower polycarbonate dome mounting bracket not included S2000 MW22C MSH 7615 01 1 4 in monochrome camera CCIR version 22x zoo...

Страница 7: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Introduction 5 Figure 1 Exploded View...

Страница 8: ...lag type screws or bolts with lock and flat washers Choose one of the two available four 4 hole mounting patterns Lift the Housing to the Mounting Bracket and connect it using the four 4 pre installed...

Страница 9: ...TB3 5 CI Command in RJ 45 COMM RELAY J3 J3 1 CI Command in J3 2 RELAY NC Relay normally closed J3 3 VSSA Ground J3 4 RO Response out J3 5 CI Command in J3 6 RELAY C Relay common J3 7 RELAY NO Relay no...

Страница 10: ...ry pressurized air 3 If spots streaks or stains appear on the exterior they can be removed with a solution of mild soap or isopropyl alcohol and water using a lint free soft paper towel Dry with clean...

Страница 11: ...from countries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following inform...

Страница 12: ...types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are not suitable for CCTV applications Choose a cable type by referring...

Страница 13: ...vidually shielded twisted pair in a single jacket This configuration is the most convenient for RS 422 RS485 applications Single twisted pair is also a suitable cable Choose a Belden cable type by ref...

Страница 14: ...luded Power Consumption 48 0 W nominal heater included Heat Equivalent 2 7 btu min 0 6 kg cal min Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage...

Страница 15: ...rogramming is done in real time with joystick and push buttons Preset Solving Speed 1 second nominal Preset Repeatability 0 3 maximum Alarm Capabilities 4 alarm inputs Individual input enable disable...

Страница 16: ...n composite video signal automatically detected upon power up RS 485 protocol utilizes full tri state outputs for daisy chain capability Control Display On screen menu driven system allowing full conf...

Страница 17: ...sized to accommodate provided 3 8 in 9 5 mm hardware Lower Dome Clear Acrylic impact resistant Dimensions See Table 6 and Figure 2 Configuration Width W in mm Height H in mm Depth D in mm Housing Alon...

Страница 18: ...ssembly 40 to 105 F 40 to 40 5 C Outdoors with sun exposure with Heater Blower Assembly and Sunshield 40 to 122 F 40 to 50 C Note The Sunshield cannot be used with the S2000 MSH CM Ceiling Mount Brack...

Страница 19: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Technical Information 17 NOTES...

Страница 20: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712...

Отзывы: