6
2.1.2 Ceiling Mounting
The ceiling mounting plate must be attached to a structural object such as concrete that will support
the weight of the mount and dome camera.
This figure shows how to twist and lock the housing
with pipe.
1. Select a suitable mounting location
and verify there is sufficient cable to
connect with cables from the
housing.
2. Mark and drill mounting holes on the
surface using the ceiling mount
flange as a template.
3.
Secure the mounting plate to the
wall using the hardware provided or
appropriate for the mounting
surface.
4. Pull out cables required to connect to
the dome camera from the ceiling.
5. Attach the ceiling mount plate using
plastic anchors and screws; route
cables through the locking nut.
6. Attach 1.5 inch adapter to the pipe
and fix it using set screw on the
adapter.
7. Route cables through the pipe.
Tighten the housing with the pipe
using the socket.
8. Attach the housing’s safety wire to
the ceiling mount’s M6x35 tapping
screw.
9. After connecting cables, fix the pipe
to the ceiling mount using the locking
nut.
10. Tighten set screws of the socket
and locking nut with the supplied
wrench.