DIP Switch Setting
DIP Switch SW1 is used to set the camera dome ID (address).
Setting the DIP Switch
The S10-CH Mini Camera Dome provides up to 63 selectable camera IDs with poles 1 – 6 of the DIP switch.
Refer to Figure 1 and access DIP SW1 to set camera ID. (Keypad/control system must have 1-63 addresses
available; address 0 is camera 256.)
Factory default: Camera ID = 1, Vicon Baud Rate: 4800 bps
Baud Rate
Protocol
ID Set
Termination
ID Setting
Camera IDs are set using poles 1-6 on DIP switch SW 1:
(1-ON, 0-OFF) (1
Î
10)
DIP Switch
Setting
ID Value
DIP Switch
Setting
ID Value
DIP Switch
Setting
ID Value
100000XXXX
1 111010XXXX
23 101101XXXX
45
010000XXXX
2 000110XXXX
24 011101XXXX
46
110000XXXX
3 100110XXXX
25 111101XXXX
47
001000XXXX
4 010110XXXX
26 100011XXXX
48
101000XXXX
5 110110XXXX
27 100011XXXX
49
011000XXXX
6 001110XXXX
28 010011XXXX
50
111000XXXX
7 101110XXXX
29 110011XXXX
51
000100XXXX
8 011110XXXX
30 001011XXXX
52
100100XXXX
9 111110XXXX
31 101011XXXX
53
010100XXXX
10 000001XXXX
32 011011XXXX
54
110100XXXX
11 100001XXXX
33 111011XXXX
55
001100XXXX
12 010001XXXX
34 000111XXXX
56
101100XXXX
13 110001XXXX
35 100111XXXX
57
011100XXXX
14 001001XXXX
36 010111XXXX
58
111100XXXX
15 101001XXXX
37 110111XXXX
59
000010XXXX
16 011001XXXX
38 001111XXXX
60
100010XXXX
17 111001XXXX
39 101111XXXX
61
010010XXXX
18 000101XXXX
40 011111XXXX
62
110010XXXX
19 100101XXXX
41 111111XXXX
63
001010XXXX
20 010101XXXX
42
101010XXXX
21 110101XXXX
43
011010XXXX
22 001101XXXX
44
20
•
XX183-01-02 Rev 808 S10-CH Camera Dome System