background image

 

2

Installation 

Connectors and Controls 

 

 

Reset Button 

 

Rear Panel 

 

1. Ethernet 

Port

 

The camera connects to the Ethernet via a standard RJ-45 connector. Supporting NWay 

(auto negotiation), this IP camera can auto detect the speed of local network segment 

(10Base-T/100Base-TX Ethernet). The camera supports PoE, so it can be powered through 

the Ethernet port as well. 
 

2. Reset 

Button 

To reset the camera back to factory defaults, follow the steps below: 

Step 1: 

Switch off the camera by disconnecting the power cable. 

Step 2: 

Press and continue to hold the reset button. Reconnect the power cable while 

continuing to hold the reset button. 

Step 3: 

Keep holding the reset button depressed about 6 seconds and then release it. The 

unit will start up with factory default settings. 
 

3. Audio 

Input/Output 

 

Not supported by ViconNet (for future use). 
 

4. 

Action LED Indicator

 

The LED will light up after IP camera has successfully completed the boot process. 

 

XX194-00-03 Rev 110 MP-955 Series Megapixel Camera 

 

Содержание I-Onyx MP-955

Страница 1: ...g To prevent fire or shock hazard do not expose the unit to rain or moisture Copyright 2010 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and i...

Страница 2: ......

Страница 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Страница 4: ......

Страница 5: ...nts Introduction 1 Installation 2 Connectors and Controls 2 Lens Adjustments 3 Connections 4 Camera Configuration 5 ViconNet Configuration 16 Appendix 22 Shipping Instructions 25 Network Cable 26 Tech...

Страница 6: ...y will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when possible to prevent damag...

Страница 7: ...a 1 3 megapixel resolution color camera while the MP 955DN provides day night functionality Equipped with a 100 Mbps LAN interface board the cameras allow direct plug in to a network switch Images rec...

Страница 8: ...ra back to factory defaults follow the steps below Step 1 Switch off the camera by disconnecting the power cable Step 2 Press and continue to hold the reset button Reconnect the power cable while cont...

Страница 9: ...gapixel camera to maintain the detail provided by the megapixel camera The supplied 4 2 lens has an adjustment ring for focus Use the small handle to turn the ring clockwise for Near and counter clock...

Страница 10: ...appropriate power source 2 When powering with PoE connect camera s Ethernet port to an Ethernet RJ 45 connector If your camera has built in PoE you can regard it as a Powered Device PD and connect it...

Страница 11: ...192 168 0 100 Make sure the IP camera and your PC are on the same network subnet mask segment before attempting to access the camera Note All cameras are factory set to the same default IP address to...

Страница 12: ...X is not required to configure the camera or for it to work in ViconNet but it is required to view video through the browser If you want to view video through the browser install ActiveX at this time...

Страница 13: ...Vicon recommends using 254 as the last octet Consult your IT administrator as required Be sure to correctly check either Dynamic IP Address DHCP or Static IP Address Vicon recommends a Static IP Addr...

Страница 14: ...ith the Nucleus These must be set manually or synchronized to an external network time server This screen allows you to synchronize the time and date with a network time server if this option is selec...

Страница 15: ...Encoder Type selects the type of compression MPEG 4 or M JPEG This choice changes the menu for M JPEG mode a Video Quality field 1 100 displays instead of Video Bitrate Video Maximum Bitrate Bitrate...

Страница 16: ...Min Max Bit Rate High 1Mbps 4 6Mbps Middle 500kbps 2 6Mbps Low 300 kbps 1 8Mbps Table 3 Constant Bit Rate Guidelines M JPEG Mode Video Settings Time Frame at Quality Level 50 is Recommended Resolutio...

Страница 17: ...eck the Lens Compensation box if you are using the 3 3 12 mm integral lens provided Some of the fields displayed in this screen change according to the selections made White Balance Mode adjusts the c...

Страница 18: ...est the Slowest shutter speed is 1 5 sec and AGC Gain can be set 1 255 slide scale If any other white balance option is selected Exposure Mode can also be Manual If Exposure Mode is set to Manual the...

Страница 19: ...e upgraded use the Firmware screen See upgrade instructions Factory Defaults To return the camera to its factory defaults select the Factory Default screen Click button when settings are complete XX19...

Страница 20: ...Duplex WAN Port Auto Detect ToS Disabled ToS ToS Priority Normal Service HTTP Port 80 Search Server Port 1 6005 Host Settings Port Mapping Search Server Port 2 6006 IP Address 192 168 0 2 SNTP NTP Ser...

Страница 21: ...ideo Mirror Not checked Lens Compensation Checked NightTime Gain Threshold 80 color camera only White Balance Mode Auto Exposure Mode Auto Sharpness 192 AGC Gain 61 Maximum Auto Shutter Speed Slowest...

Страница 22: ...ONYX MP 955 cameras only need to be added once in the Nucleus for the entire system 1 From the ViconNet Main window click The Setup Site Selection window is displayed showing a list of all currently...

Страница 23: ...te The camera will only be detected if they are on the same LAN as the PC Cameras that are not on the LAN have to be added manually See procedure below A message will display to add a User Name and Pa...

Страница 24: ...ample screen account is the user name in this case After Login the camera settings can be modified as needed 9 Click Save to save your settings and Close to exit the window An Undo button is provided...

Страница 25: ...lect the camera that you want to edit The Camera Details area will become enabled 3 Make the changes in the fields that are required 4 Click Save to save your changes and Close to exit the window An U...

Страница 26: ...etwork the following items must be considered The number of cameras on a switch with respect to switch capabilities and system bandwidth mapping Bandwidth limitations on ports connected to workstation...

Страница 27: ...XX194 00 03 Rev 110 MP 955 Series Megapixel Camera 21...

Страница 28: ...amera using the web browser as described in Camera Configuration section of this manual The IP Utility is designed with a user friendly interface When the utility is opened the interface will display...

Страница 29: ...ord to connect to the camera default user is Admin and default password is 123456 4 Click Apply button 5 Account and Password fields are automatically entered for the camera 1 Enter Account and Passwo...

Страница 30: ...are type want to upgrade 2 Click Browse button to select the firmware file you will be using for the upgrade as you obtained from Vicon Technical Support 3 Click Browse button to select the MD5 file y...

Страница 31: ...ham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name...

Страница 32: ...Choose a Belden cable type by referring to the characteristics listed below The Table below should be used as a guideline when cables other than Belden are used Materials and construction must follow...

Страница 33: ...ive Consumption Rate Standard network protocol type using IP addressing scheme and separate PC application software Camera can be setup from NVRs DVRs and Workstations System macros can be configured...

Страница 34: ...ment Lens Mount Camera Mounting Shipping Dimensions Shipping Weight Shipping Volume Operating Temperature Range Humidity External Controls Connectors Network Software Security System Status Red LED Re...

Страница 35: ...n the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hard...

Страница 36: ...pe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office...

Отзывы: