Network Considerations
The MP-955 IP Cameras can be connected to any ViconNet network (Version 5 software). ViconNet NVRs,
DVRs and Workstations can be used for live viewing and recording of network-streamed video. A network
can be as simple as a single MP-955 camera connected to a ViconNet Workstation or can be complex with
the addition of several networks interconnected via WAN.
When adding an MP-955 IP Camera to the ViconNet network, the following items must be considered:
•
The number of cameras on a switch with respect to switch capabilities and system bandwidth mapping.
•
Bandwidth limitations on ports connected to workstations (using 100 or 1000 Mbps).
•
Workstation capabilities such as processing speed, disk write speed and display card strength.
•
Storage size and location types including local Workstation recording, attached SCSI RAID and
integrated NAS/SAN devices.
Refer to the ViconNet workstation manual XX113-3X for complete information on operation. A copy