![Vicon HOV Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/vicon/hov/hov_manual_1012681007.webp)
EN - English - I
nstruc
tions manual
5
Fasten the camera with the 1/4" screw. If necessary,
use the supplied spacers to correctly position the
camera and optics (03).
02
03
01
Fig. 02
Reposition the internal slide by tightening the
previously loosened screws.
The camera’s power supply cable conductors must be
tied up next to the terminal. Make sure the signalling
and power supply cables are separated from each
other.
6.1.3 Connection to the power supply
line
This section describes how to connect the power
supply line to the housing.
Insert the cables for the connection to the power
supply line inside the housing through the cable
glands. The cable glands are suitable for cables with a
diameter comprised between 5 and 10mm. The cable
inside the housing must be long enough to allow the
connection and the appropriate locking of the cable
glands.
Remove the conductors protective sheathing and
connect them to terminal J1 (
Make sure the earth conductor is at least 10mm.
longer than the others. The power supply cable
conductors must be tied up next to the terminal.
Make sure the signalling and power supply cables are
separated from each other
6.1.3.1 Type of cable
The cable used for the connection to the power
supply line must be suitable for the intended use.
Comply with the current national standards on
electrical installations.
6 Installing and
assembling
h
Only specialised personnel should be
allowed to install and assemble the device.
6.1 Installation
6.1.1 How to open the housing
To open the housing, loosen the 2 screws on the side,
turn the cover and the upper half of the body about
the opening hinge axis.
Fig. 01
In this way there will be easy access to the inside of
the housing.
6.1.2 Camera installation
This section describes how to install the camera
inside the housing. It should be remembered that the
power supply can be taken from the circuit supplied
after making sure it is correct one.
Open the housing as described before.
Extract the internal support slide by partially
loosening the fastening screws (01).
Move the slide, by sliding it until the holes coincide
with the slide locking screws (02).
Содержание HOV
Страница 1: ...HOV Side opening aluminium housing ...
Страница 2: ......
Страница 3: ...HOV Side opening aluminium housing ...