Vicon HOV Скачать руководство пользователя страница 5

EN - English - I

nstruc

tions manual

3

1  About this manual

Before installing and using this unit, please read this 
manual carefully. Be sure to keep it handy for later 
reference.

1.1  Typographical conventions

 

g

DANGER! 
High level hazard. 
Risk of electric shock; disconnect the 
power supply before proceeding with any 
operation, unless indicated otherwise.

 

h

WARNING! 
Medium level hazard. 
This operation is very important for the 
system to function properly. Please read 
the procedure described very carefully and 
carry it out as instructed.

 

j

INFO 
Description of system specifications. 
We recommend reading this part carefully 
in order to understand the subsequent 
stages.

2  Notes on copyright and 
information on trademarks

The quoted names of products or companies are 
trademarks or registered trademarks.

3  Safety rules

 

h

The manufacturer declines all responsibility 
for any damage caused by an improper use 
of the appliances mentioned in this manual. 
Furthermore, the manufacturer reserves 
the right to modify its contents without any 
prior notice. The documentation contained 
in this manual has been collected with great 
care, the manufacturer, however, cannot 
take any liability for its use. The same thing 
can be said for any person or company 
involved in the creation and production of 
this manual.

•  The device must be installed only and exclusively 

by qualified technical personnel.

•  Before any technical work on the appliance, 

disconnect the power supply.

•  Do not use power supply cables that seem worn 

or old.

•  Never, under any circumstances, make any 

changes or connections that are not shown in 
this handbook: improper use of the appliance 
can cause serious hazards, risking the safety of 
personnel and of the installation.

•  Use only original spare parts. Not original spare 

parts could cause fire, electrical discharge or other 
hazards.

•  Before proceeding with installation check the 

supplied material to make sure it corresponds 
to the order specification by examining the 
identification labels (

"4.2 Product markings", page 4

).

•  This device was designed to be permanently 

installed on a building or on a suitable structure. 

•  When installing the device, comply with all the 

national standards.

•  The electrical system of the building on which 

the device is to be installed must have a two-pole 
protection circuit (circuit breaker) complete with 
an automatic two-pole switch which provides 
protection for earth fault current (circuit breaker 
+ differential) with a minimum distance between 
contacts of 3 mm. 

•  Any device which could be installed inside the 

housing must comply with the current standards.

Содержание HOV

Страница 1: ...HOV Side opening aluminium housing ...

Страница 2: ......

Страница 3: ...HOV Side opening aluminium housing ...

Страница 4: ... 6 1 1 How to open the housing 5 6 1 2 Camera installation 5 6 1 3 Connection to the power supply line 5 6 1 3 1 Type of cable 5 6 1 4 Board and connection 6 6 1 5 Heater installation 6 6 1 6 Camera power supply installation 6 6 1 7 Blower installation 7 6 1 7 1 100 240Vac power supply 8 6 1 7 2 12Vdc or 24Vac power supply 8 6 1 8 Cooling device 8 6 1 9 Wiper system 9 6 1 10 Closing the housing 9 ...

Страница 5: ...e same thing can be said for any person or company involved in the creation and production of this manual The device must be installed only and exclusively by qualified technical personnel Before any technical work on the appliance disconnect the power supply Do not use power supply cables that seem worn or old Never under any circumstances make any changes or connections that are not shown in thi...

Страница 6: ...n Innovative and stylish housing designed to simplify installation and servicing HOV ensures total protection against all environmental conditions Due to its side opening the accessibility to the camera lens and all its connections is made far easier Its weatherproof features are ensured by neoprene rubber gaskets and 3 cable glands with their specific gaskets or by the sealing gaskets when instal...

Страница 7: ... at least 10mm longer than the others The power supply cable conductors must be tied up next to the terminal Make sure the signalling and power supply cables are separated from each other 6 1 3 1 Type of cable The cable used for the connection to the power supply line must be suitable for the intended use Comply with the current national standards on electrical installations 6 Installing and assem...

Страница 8: ...he relative terminal of the J1 connector Board description J1 Input power supply terminal 100 240Vac or 24Vac 12Vdc J2 Output power supply terminal same voltage coming from J1 J3 Output terminal for heating J4 Anti opening switch terminal optional J5 Camera power supply output terminal J7 Connector for power supply J8 Connector for fan Tab 01 The camera output voltage can be 12Vdc or 24Vac in rela...

Страница 9: ...inside the body of the housing using the corner bracket and supplied screws Blow direction Fig 09 Using the screws supplied with the kit assemble the power supply with the support bracket 01 and the corner attachment bracket 02 using the points provided for this 01 02 Fig 07 Insert the 6 pin connector at the end of the cable into the correspondent one on the support circuit identified by J7 Fig 03...

Страница 10: ...ltage and the correct power supply kit must be chosen 6 1 7 1 100 240Vac power supply Insert the 2 pin connector at the end of the cable into the corresponding one indicated by J8 FAN on the support circuit Fig 03 page 6 Install the camera power supply supplied with the blower kit as described in the chapter 6 1 6 Camera power supply installation page 6 Close the housing 6 1 7 2 12Vdc or 24Vac pow...

Страница 11: ...e European Union there are separate collection systems for used electrical and electronic products 6 1 9 Wiper system This section describes how to connect housings fitted with wiper systems For these versions it is not necessary to install any component on the inside because they are supplied complete with everything that is needed depending on the model ordered Open the housing as described prev...

Страница 12: ...55 EN60529 with bracket with internal cable channel IP44 EN60529 for models with cooling blower and double filter 10 Technical specifications 10 1 General Aluminium construction Sunshield in ABS Epoxypolyester powder painting RAL9002 colour Stainless steel external screws Supplied with instruction manual desiccant bag accessories for camera and lens mounting 10 2 Mechanical Cable glands 3xM16 Glas...

Страница 13: ...nual 11 11 Technical drawings j jThe values are in millimeters 76 98 27 131 160 213 70 40 188 113 60 88 88 400 225 13 39 39 62 140 53 514 176 100 70 250 70 A A B B A A B B 9 0 R100 400 430 412 USABLE AREA USABLE AREA Fig 14 HOV ...

Страница 14: ...dquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon security com ...