background image

To properly clean your humidifier we recommend the separate processes of Scale Removal and 

Disinfecting shown below. These two processes must be performed separately. 
All maintenance should be done in the kitchen or bathroom on a water resistant surface near  
a faucet. 

DO NOT

 wash any components of this humidifier in the dishwasher.

Instructions for Scale Removal

6

7

Using Your Humidifier

    (Continued)

Mist Outlet

This humidifier features a directional Mist Outlet. Use this feature to direct the mist where you want 
it most.
The Outlet will rotate up to 180º.

Using The Demineralization Cartridge:

This humidifier has been designed to be used with the Protec PDC51V2  
or PDC51CV2 Demineralization Cartridge (not included). In hard water  
areas, use of distilled water or a demineralization cartridge with tap water  
will help minimize the production of white dust. Cartridges can be ordered  
through Consumer Relations; see back of this manual.

Daily Maintenance

For best results, use fresh clean water every day. 

Weekly Cleaning

 Step 2

 Step 1

 Step 4

 Step 3

MINUTES

 Step 6

 Step 5

 Step 7

VUL545 and VUL525

Using Vicks VapoPads

Your humidifier can be used with Vicks VapoPads

 

to provide up to 8 hours of soothing vapors.  

One free sample of the Vicks Soothing Menthol VapoPad is included with your humidifier. To use 
your unit with Vicks VapoPads:

1. 

Open VapoPad Door by pressing the button.

2.  

Open VapoPad by tearing notch on pad bag. 

DO NOT

 touch pad with hands. If pad is touched  

DO NOT

 rub face or eyes as it may cause irritation.

3.  

Insert Vicks VapoPad with angled end facing towards the product. Push pads into VapoPad Slot. 

Close door.

4. 

After 8 hours, discard VapoPad. Push button to eject VapoPads.

To continue using VapoPads, repeat steps 1-4.

VapoPad Recommended Usage:

• Not recommended for infants under 10 lbs (4.5 kg).
• For children between 10-22 lbs (4.5-10 kg ) do not use more than 2 pads in a 24 hr period.
Scent Pad Ingredients: VSP-19, VSP-19-CAN:

 

Eucalyptus Oil, Menthol, Glycol, Cedar Leaf Oil & Others

 Step 2

 Step 3

 Step 4

1.  

Turn off and unplug the humidifier.

2.  

Remove Water Tank from Base. Remove Tank Cap, taking care that the rubber Cap Gasket

 

does not come off. Empty water from Water Tank and Base.

3.  

If Antimicrobial Cleaning Product is installed, remove Antimicrobial Cleaning Product and set aside.  

DO NOT

 clean Antimicrobial Cleaning Product. This will damage the Antimicrobial Cleaning Product.

4.  

Add 2 cups of undiluted distilled white vinegar to Water Tank. Replace Tank Cap and swish 

vinegar solution around in Tank. Place Tank on Base. Vinegar solution will drain into Water 

Reservoir and loosen mineral buildup (scale) on Nebulizer and Float as they soak in the  

solution. It will also loosen scale on bottom of Water Tank.

5.  

Soak for 15-20 minutes. 

6.  

After soaking, unlock Tank Cap and pour solution out in sink. Pour solution from  

Water Reservoir out in sink. Wipe Nebulizer and Float with soft cloth to remove loosened 

mineral deposits. 

7.  

Rinse Water Reservoir and Water Tank until smell of vinegar (for Scale Removal process)  

or bleach solution (for Disinfecting process) is gone. Make sure water does not enter the  

fan opening (vented opening on right side of Reservoir) or Power Knob.

 CAUTION:

 

DO NOT SUBMERGE BASE IN WATER. DOING SO WILL DAMAGE THE  

       HUMIDIFIER AND VOID THE WARRANTY.

HOURS

1

2

3

4

5

6

7

11

8

9

10

12

 Step 1

Содержание VUL525 Series

Страница 1: ...u have any questions about the operation of your Vicks Filter Free Ultrasonic Cool Mist Humidifier call our toll free Consumer Relations line at 1 800 VAPOR 1 2 or e mail us at ConsumerRelations Helen...

Страница 2: ...ar cleaning Refer to and follow cleaning instructions 8 DO NOT operate outdoors this appliance is intended for indoor residential use only 9 DO NOT cover or insert objects into any openings on the uni...

Страница 3: ...Tank Cap by turning counterclockwise left Fill Tank with cool water DO NOT fill with warm or hot water 2 Replace Tank Cap by turning clockwise right aligning arrow to lock symbol Be sure Gasket is in...

Страница 4: ...nd facing towards the product Push pads into VapoPad Slot Close door 4 After 8 hours discard VapoPad Push button to eject VapoPads To continue using VapoPads repeat steps 1 4 VapoPad Recommended Usage...

Страница 5: ...C rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and i...

Страница 6: ...s warranty does not cover the filters pre filters UV bulbs or other accessories if included except for material or workmanship defects Call us toll free at 1 800 827 6712 or e mail ConsumerRelations H...

Страница 7: ...ns fournies 8 NE PAS l employer au grand air il est r serv l usage r sidentiel l int rieur 9 NE couvrir AUCUN orifice de l appareil et ne RIEN ins rer dans les orifices 10 NE PAS essayer de r parer ou...

Страница 8: ...aiguilles d une montre vers la gauche Remplissez le r servoir d eau froide N utilisez PAS d eau ti de ou d eau chaude 2 Remettez le bouchon du r servoir en le tournant dans le sens des aiguilles d une...

Страница 9: ...que d crit ci dessous Proc der au d tartrage et la d sinfection s par ment Tout entretien devrait tre effectu dans la cuisine ou la salle de bains sur une surface qui r siste l humidit pr s d un robi...

Страница 10: ...pareil Cet appareil a t soumis aux tests d usage et d clar conforme aux limites tablies pour appareils g n rateurs de fr quences ISM conform ment la partie 18 des r glements de la FCC Ces limites ont...

Страница 11: ...ctions D Cette garantie ne couvre pas les filtres pr filtres ampoules UV et autres accessoires si compris except pour les d fauts de mat riau ou de main d oeuvre REMARQUE SI VOUS AVEZ UN PROBL ME VEUI...

Страница 12: ...las manos secas NUNCA estire el cable 7 El aparato requiere limpieza regular Consulte y siga las instrucciones de limpieza 8 NO opere en exteriores este aparato est dise ado s lo para uso en interior...

Страница 13: ...e la habitaci n cerca del humidificador Este residuo mineral se conoce com nmente como polvo blanco Cuanto mayor sea el contenido de minerales dureza en el agua mayor el potencial de un humidificador...

Страница 14: ...ente vea el reverso de este manual Mantenimiento Diario Para obtener mejores resultados utilice agua limpia y fresca todos los d as Paso 2 Paso 1 Paso 4 2T Paso 3 Para limpiar adecuadamente su humidif...

Страница 15: ...w VicksHumidifiers com Por favor aseg rese de especificar el n mero de modelo VUL525 o VUL545 Especificaciones Clasificaci n El ctrica Los modelos VUL525 y VUL545 de Vicks est n clasificados en 120V 6...

Страница 16: ...NSULTE SU GARANT A NO DEVUELVA EL PRODUCTO LUGAR ORIGINAL DE COMPRA NO INTENTE ABRIR LA CARCASA DEL MOTOR USTED MISMO HACERLO PODR A ANULAR SU GARANT A Y CAUSAR DA O AL PRODUCTO O DA OS CORPORALES Sol...

Страница 17: ...ibuted by Kaz Canada Inc a Helen of Troy Company 6700 Century Avenue Suite 210 Mississauga Ontario L5N 6A4 www VicksHumidifiers com Certain trademarks used under license from The Procter Gamble Compan...

Страница 18: ...5 9 IN W5 5 x H8 5 Material Page count 32 Revision 4 Release Date Date 08APR21 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 100 Magenta 100 Yellow 100 Black 100 Hele...

Отзывы: