The Air-Cleaning DynaFilter
®
The Vick Cool Mist Humidifier includes the exclusive Protec Air Cleaning
DynaFilter PK14-3W.
Under normal environmental conditions, the filter cartridge should
be replaced every two months. Replacement time will vary depending
upon the concentration of pollutants in the air. If you notice heavy dirt
accumulation on the filter or if the humidifier output is significantly
reduced,
it’s time to change to a new DynaFilter!
Protec DynaFilter PK14-3W cartridges are available at leading pharmacies
and drug departments.
Operating Instructions
1.
CAUTION: UNRAVEL CORD BEFORE USE
.
Failure to do so could cause overheating and
possible fire hazard.
Always disconnect cord at wall plug before removing the Top Housing or when humidifier is
not in use.
2.
INSERT DynaFilter CARTRIDGE.
Simply remove the outer protective wrap and insert the DynaFilter
cartridge into the recess of the Top Housing (WHITE FILTER OUT).
Inspect used DynaFilters. If you notice heavy dirt accumulation, it’s time to replace the DynaFilter.
3.
PLACE HUMIDIFIER IN A SAFE POSITION
on floor, table or other firm, FLAT and LEVEL surface.
Protect rug, floor or furniture by placing unit on a waterproof non-conducting pad or mat for
protection against inadvertent spillage.
Do not
place any object over the humidifier; it could
block air openings.
Cord should be out-of-the-way, where it cannot be pulled or stepped on.
When used therapeutically, the humidifier should be placed at least 4 feet from bedside and out
of the reach of children.
4.
FILL CAREFULLY.
The exclusive Kaz FillChannel™ permits convenient filling without removing
the Top Housing. Pour cool tap water into FillChannel. Fill until water level reaches Water Level
Indicator on the front of bowl.
IMPORTANT:
DO NOT OVERFILL, as this will cause water spillage and possible damage to
floors or furniture.
5.
PLUG IN HUMIDIFIER.
Plug power cord into 110-120 volts AC outlet.
CAUTION: DO NOT PLUG IN THE CORD WITH WET HANDS; ELECTRIC SHOCK COULD RESULT.
This product has a polarized plug (one blade is wider than the other) as a safety feature.
The plug will fit into a polarized outlet only one way. If the plug does not fit properly into the
outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
Do not attempt to
defeat this safety feature.
6.
IMPORTANT:
To maintain proper operation of your humidifier, be sure to follow
Care and
Cleaning
instructions.
Care and Cleaning
Tap water will contain pollutants and minerals (scale) that can deposit on the inner surfaces of
the humidifier. Such scale can accelerate the growth of microorganisms and it is important that
periodic cleaning is performed as outlined below. More frequent cleaning may be necessary if
you notice a heavy build-up of scale.
Inspect the DynaFilter
Remove and inspect the DynaFilter cartridge for dirt and dust accumulation. If you notice heavy
accumulation, the filter needs to be replaced. If filter is not changed regularly, dust and other
pollutants will clog the filter, impair air flow, reduce the efficiency of the humidifier and may
damage the motor.
Daily Maintenance
1.
Unplug cord from electrical outlet.
2.
To remove top housing
turn locking screw counterclockwise
and lift (
Fig. A
). Place top housing
upside down
on a flat surface.
Use lift tabs on both sides of Top Housing to remove.
Do not
set
down on the Pickup Tube. Rinse Base, wipe clean, and dry with a
clean cloth or paper towel.
3.
Wipe exterior surfaces of the Top Housing with a soft, dry cloth.
CAUTION: DO NOT
USE WATER TO CLEAN THE TOP
HOUSING. ELECTRIC SHOCK MAY RESULT OR HUMIDIFIER MAY
BE DAMAGED.
DO NOT
IMMERSE TOP HOUSING IN WATER.
4.
To reassemble, align locking screw with hole in tank.
Turn screw
clockwise
to tighten (
Fig. B
).
NOTE:
DO NOT
OVER TIGHTEN
SCREW. Humidifier is now ready for use.
Weekly Maintenance-Removing Scale
1.
Unplug cord from electrical outlet.
2.
To remove top housing
turn locking screw counterclockwise
and
lift. Place top housing
upside down
on a flat surface (
Fig. A
).
Do not
set down on the Pickup Tube.
3.
Empty any remaining water from Base.
4.
Carefully loosen the Pickup Tube from the housing by holding the Disk
and rotating the Pickup Tube counterclockwise in the direction of the
“OFF” arrow located at the base of the Pickup Tube (
Fig. C
).
5.
Soak Pickup Tube in undiluted white vinegar. Let stand for 20 minutes.
6.
Dampen a soft, clean cloth or sponge with undiluted white vinegar and
wipe out Base, Pickup Tube and walls around the Pickup Tube.
CAUTION: DO NOT
use soap, detergents or abrasive cleaners.
7.
Rinse Pickup Tube and Base thoroughly in clean, warm water until
scale particles are removed.
8.
Wipe exterior surfaces of the Top Housing with a soft, dry cloth.
DO NOT
IMMERSE OR SPRAY WATER ON THE TOP HOUSING.
You are now ready to disinfect the base.
E
F
ON
OFF
Fig. C
OPEN
LOCK
Fig. A
OPEN
LOCK
Fig. B