1) Even if there is no voltage indication, there may be voltage on the circuit. Do not

rely on NCV detector as the only way to detect voltage.

2) Voltage detecting may be affected by power socket design, type of insulation and its

thickness and other factors.

3) Interference sources in the external environment, such as flashing light, motor,

would cause wrong signal to activate alarm function.

4.10 DIODE AND CONTINUITY TEST

4.10.1 Insert the black test lead into “COM” terminal and the red one into “VΩmA”

terminal (the polarity of red lead is “+”);

4.10.2 Turn the rotary switch to “Ω

” range, and press “SELECT/

” key to choose

” mode;

4.10.3 Forward measurement: connect red test lead to the positive polarity and the

black test lead to the negative polarity of the diode. LCD will display the approx. value of

forward voltage drop;

4. 10.4 Backward measurement: connect red test lead to the negative polarity and the

black test lead to positive polarity of the diode. LCD will display “OL”;

4.10.5 The complete diode test includes forward and backward measurement, if the

result doesn’t meet the descriptions above; it means the diode is broken;

4.10.6 Press “SELECT/

” key to select the continyity measurement mode;

4.10.7 Connect test leads to two points of tested circuit, if the resistance is less than 50

Ω, the built‐in buzzer sounds.

NOTE:

1) DO NOT input voltage at “

Ω

” range.

2) When test circuits, make sure the power is off and all capacitors are discharged. Any

negative potential or AC signal will activate the buzzer.

4.11 TEMPERATURE MEASUREMENT

4.11.1 Turn the rotary switch to “

/

” range. Press “SELECT/

” key to select

or

mode.

4.11.2 Insert the cold end (free end) of thermocouple in “VΩmA(+)” and “COM(‐)”

terminal, and put the working end (temperature measuring end) of thermocouple on the

surface or inside the tested object. Then LCD will display the temperature of tested

object, and the reading is in

/

(when the polarity is contrary. The reading will

decrease when the temperature of the tested object increase).

NOTE:

1) When the input terminal is open circuit, it will display the environment

temperature.

2) To ensure measure accuracy, do not replace the temperature probe unless it is

necessary.

3) Do not input voltage at temperature range.

5. MAINTENANCE

This meter is a precise instrument. Any modification to the circuit is not allowed.

NOTE:

1) Don’t input the voltage value higher than 600V DC or ACrms.

2) Don’t input voltage at current, resistance, diode or continuity range.

3) Don’t make any measurements when the battery is not properly installed or the

back cover isn’t fixed.

4) Before replacing battery or fuse, please remove the test leads from the measuring

point and turn off the power.

5) Keep the meter away from water, dust and shock.

6) Don't expose the meter under high temperature, high humidity, combustible,

explosive and strong magnetic place.

7) Wipe the case with a damp cloth and detergent. Do not use abrasives and alcohol to

clean the meter.

8) If the meter will not be used for a long time, please take out the battery to avoid

leakage damage.

9) When “

” symbol is displayed, please replace the battery according to the

following steps:

1

Remove the holster at first.

2

Screw off the fixing screws of the battery door and remove the cover;

Содержание VC837

Страница 1: ...n and range to avoid wrong operation 2 5 Move the test leads away from test points when switching to other function 2 6 Don t input voltage in current terminal 2 7 Don t make any modification to the c...

Страница 2: ...onds Overload protection 0 5A 250V fuse and 10A 250V fuse 3 2 5 AC Current ACA Range Accuracy Resolution 600uA 1 5 5 0 1 A 6000uA 1 A 60mA 10 A 600mA 100 A 6A 1mA 10A 2 0 10 10mA Maximum voltage drop...

Страница 3: ...1832 750 1 0 5 750 1 5 15 Thermocouple K type WARNING do not input voltage at this range Operation 4 1 Panel Description LCD Display the data and unit symbol Number Feature Description 1 Relative REL...

Страница 4: ...e is no measurement in 15 minutes the meter will automatically power off and enter sleep mode One minute before sleep mode the buzzer will beep for 5 times to remind user Press any button or turn the...

Страница 5: ...s the default when you turn on the meter AUTO symbol displayed Press RANGE REL key can change to Manual range the available ranges are 600uA 6000uA 60mA 600mA 6A 10A 4 4 3 Connect test leads to the te...

Страница 6: ...ance value NOTE 1 Don t input voltage or current under capacitance ranges 2 Press RANGE REL to clear the reading before testing to assure the accuracy 3 There is only the auto range mode under the cap...

Страница 7: ...RATURE MEASUREMENT 4 11 1 Turn the rotary switch to range Press SELECT key to select or mode 4 11 2 Insert the cold end free end of thermocouple in V mA and COM terminal and put the working end temper...

Страница 8: ...ter does not work properly please check the meter as following steps If the problems still cannot be solved please refer to repairing center or contact the local dealers Fatult Solution No reading on...

Отзывы: