background image

6

Fixturlaser XA 

Evaluating the Results

1. 

Vertical results are displayed at the top of the 

screen, horizontal results at the bottom.

2. 

Green coupling icons indicate values which are 

in tolerance.

3. 

Orange values are within 2x tolerance.

4.

 Red values are more the 2x the tolerance level.

M E A S U R E

Содержание Fixturlaser XA

Страница 1: ...Fixturlaser XA Q U I C K T I P S 2013 VibrAlign Inc Fixturlaser XA...

Страница 2: ...ge on hub nearest to you and adjust the movable shaft to within 20 mils 0 020 of the stationary hub 2 Correct Obvious Soft Foot Loosen all the bolts and find any obviously loose shim packs Add shims a...

Страница 3: ...a Final Soft Foot Correction Loosen one bolt at a time and check for soft foot with a 2 mil 0 002 shim or feeler gauge Correct any foot with 2 mils or more of soft foot then tighten the bolt before pr...

Страница 4: ...n menu on the display unit touch the horizontal alignment icon 2 Select the RPMs of the equipment to set the alignment tolerances then press OK 3 The lasers will turn on and the screen graphic will sh...

Страница 5: ...the near est 1 8 and enter using the keypad Then press OK to move the next dimension Measure Misalignment 1 Rotate the sensors to the 9 00 position and press the flashing measurement button Note There...

Страница 6: ...ion of the circle on the screen The second reading will automatically begin after the sensors have been steady for 2 seconds 3 Rotate the sensors out of the red portion of the circle towards 3 00 When...

Страница 7: ...al results are displayed at the top of the screen horizontal results at the bottom 2 Green coupling icons indicate values which are in tolerance 3 Orange values are within 2x tolerance 4 Red values ar...

Страница 8: ...en 2 Loosen all the bolts on the movable machine 3 Follow screen instructions for removing or inserting shims Do not retighten the bolts Next Correct the Horizontal Misalignment 1 First press the live...

Страница 9: ...he machine is towards you To change the display to show either set of values larger on screen for better viewing just touch any of the four numbers 4 Continue to adjust the movable machine until both...

Страница 10: ...on the confirmation pop up screen 2 Follow the measurement steps detailed above and verify the results are within tolerance Document the Results 1 Press the file save icon 2 Press the white file name...

Страница 11: ...esources Training vibralign com training The Alignment Blog thealignmentblog com The Alignment Resource Center shaftalignment net Videos youtube com vibralign T mail Training Newsletters vibralign com...

Страница 12: ...www vibralign com 800 379 2250 530 G Southlake Blvd Richmond VA 23236 Phone 804 379 2250 Fax 804 379 0189 2013 VibrAlign Inc Version 2 0 Fixturlaser XA...

Отзывы: