3
Fixturlaser XA
Set Up
1.
Turn on the XA Display Unit.
2.
Mount the ‘S’ sensor on the stationary shaft or
coupling hub and hand tighten the nut. Turn the
sensor on by pressing the power button on the
Bluetooth module.
3.
Mount the ‘M’ sensor on the movable shaft or
coupling hub and hand tighten the nut. Turn the
sensor on by pressing the power button on the
Bluetooth module.
Start the Horizontal Alignment Program
1.
From the main menu on the display
unit touch the horizontal alignment icon.
2.
Select the RPMs of the equipment to set the
alignment tolerances, then press OK.
3.
The lasers will turn on and the screen graphic
will show the orientation of the sensors.
Aim the Lasers
1.
Loosen the green clips and slide the sensors up
or down until the line laser beams hit the middle
of the opposite sensor. Note that the sensors will
be at different elevations.
2.
The display unit screen will show green lights
next to each sensor to
confirm that the lasers have
been acquired by the sensors.
3.
Using the wrench, tighten the nuts another
half turn.
S E T U P