2 — © 2020 Viavi Solutions (21 Jan 2020)
GS-8P-384T
GS-8P-384T technical specifications
The technical specifications for this product are shown below.
System
-
Deployment
Multi-10 Gb data center
Base storage
384 TB
Max storage
768 TB
Lights Out Management (LOM)
Yes
Redundant OS drive
Yes
OS drive hot swappable
Yes
OS drive size
1 TB
RAID drive hot swappable
Yes
RAID version
50
Rail kit (Model 22113260)
Yes
Operating system
Windows 2012 R2
Physical
-
Height
20U (4 x 5U)
Width
19 in
Depth
26 in
Weight (mounted)
416 lbs
Weight (handling)
80 lbs
Media
-
Monitoring interfaces
8
Speed
1/10 Gb
Accepted transceivers
SFP/SFP+
Performance
-
Aggregate performance
40 Gbps
Power
-
Redundant power supply
Yes
Input frequency
50/60Hz
Input voltage
100V-240V Auto Select
Operational current (amps)
14.3A
BTU
5391 BTU/hr
Operational voltage
120V
Power dissipation (watts)
1716W
Relative humidity (non-
condensing)
20-80%
Temperature (operating)
50°F - 95°F / 10°C - 35°C
Temperature (storage)
-4°F - 149°F / -20°C - 65°C
1. If applicable, mounted weight includes any rail kits.
2. SFP may be any of Copper 10/100/1000, 1Gb SX/LX. SFP+ may be any of
10Gb SR/LR. QSPF+ may be any 40Gb SR/LR/BiDi/Universal.
Parts list
Each appliance comes packed in a box or several boxes.
The boxes contain the various components necessary for a
successful installation.
The boxes are not numbered as listed here. The numbers merely
represent how many boxes you should expect and what is
contained in each one.
♦
Box 1
●
1 Head unit
●
1 Rail kit
10-32 screws (4)
6mm screws (4)
Rails (2)
●
2 Power supply cables
●
1 Ethernet cable
●
2 keys for lock
●
1 USB drive containing restore image
●
1 Product Activation Information envelope
containing the product license
●
1 Quick Start Guide
●
SFP transceivers (if ordered)
♦
Box 2
●
24 RAID drives labeled
A1-1
-
A1-24
.
●
TAP media kit(s) (if ordered)
♦
For each JBOD (3), a box that contains:
●
1 JBOD Unit
●
1 Rail Kit
●
2 Power supply cables
●
Mini-SAS cable(s)
♦
A box that contains the RAID drives for each JBOD (3) :
●
24 RAID drives labeled
A2-1
-
A2-24
.
●
24 RAID drives labeled
B1-1
-
B1-24
.
●
24 RAID drives labeled
C1-1
-
C1-24
.
Before installing, ensure you received all of the parts required
for your system.