![Viavi MSAM Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/viavi/msam/msam_manual_1011694050.webp)
Chapter 4
Test Results
Signal results
Data Communications and Diphase Testing Manual
Page 34
21148872, Rev. 002
January 2016
Signal results
provides descriptions of the test results in the Signal category.
BERT results
provides descriptions of the test results in the HS Datacom or Diphase BERT
category.
Table 11
Signal results
Test Result
Description
Clock In Frequency
Frequency derived from clock input connector.
Datacom only.
Clock Out Frequency
Frequency derived from clock output connector.
Datacom only.
Rx Clock Losses
Count of the number of instances where the receive
clock was lost for a duration exceeding that specified
as the clock loss threshold since starting or restarting
the test.
Rx Data Losses
Count of the number of instances where receiver syn-
chronization was lost due to a loss of data after at least
one data transition occurred since starting or restarting
the test.
Rx Frequency
Frequency derived from receiver clock counter.
Tx Clock Losses
Count of the number of instances where the transmit
clock was lost for a duration exceeding that specified
as the clock loss threshold since starting or restarting
the test.
Tx Frequency
Frequency derived from transmission clock counter.
Table 12
BERT results
Test Result
Description
Bit Error Rate
Ratio of bit errors to received pattern data bits.
Bit Errors
Number of received bits with a value opposite that
of the corresponding transmitted bits, after pattern
synchronization has been achieved.
Block Error Rate
Ratio of block errors to the number of blocks ana-
lyzed.
Block Errors
Number of block errors received after pattern syn-
chronization has been achieved.
Character Errors
Number of characters received since test restart
that contain one or more data errors.
NOTE:
This result is only available if you are test-
ing in asynchronous mode.