6 — © 2021 Viavi Solutions (1 Nov 2021)
5.
Set Configuration Address source to Static.
6.
"Configure the Station IP address, Subnet mask, and Router
address.
"These values must be valid and usable on your network!
7.
Press F4 to save your changes and to exit the BIOS setup.
The system automatically shuts down and restarts.
Now you can log on to the IPMI web interface and change the default
password.
8.
To change the default password, open a web browser to http://
<IpAddressOfIPMIport>, and log on with the user name ADMIN in
caps and <password>.
IpAddressOfIPMIport is the station IP address you configured in step
6. The password is located on a sticker that is affixed to the body of the
applicance. The sticker looks very similar to this one.
9.
Choose Configuration > Users, and select the second user account
(ADMIN account).
10. Click Modify User, and change the password.
11. (Optional) Set up alerts.
There is no audible alarm if there is an issue with a power supply unit.
Other alerting options are available. Each must be configured separately
using details from your environment.
●
To receive email alerts, change the settings at Configuration
> SMTP.
●
To receive SNMP traps, change the settings at Configuration
> SNMP.
●
To receive Syslog messages, change the settings at
Configuration > Syslog.
You configured the IPMI port and changed the default password. You may
have also configured your system to send alerts when certain situations arise.