background image

VIAVI//Public

T-BERD/MTS 2000 Handheld Modular Test Set

T-BERD/MTS-2000 Handheld Modular Test Set

Q U I C K   C A R D

5

6.

Tap the 

Trace 

tab at the left screen top to select 

Trace view

7.

Set the toggle switch at the screen top to 

Info

.

8.

Tap the magnifying glass icons to zoom in     , 
zoom out      , or auto-zoom      the display.  
You can also pinch and zoom with your fingers.

9.

View trace results:

Trace information is shown in the upper 
display. Tap 

or

to select the acquisition 

(wavelength or pulse width) for results 
display.

Graphical results (dB versus distance) are 
shown in the center display.  

A color-coded 

Event table 

is shown in the 

lower display.  Swipe up and down to view 
all events. 

10.

Tap the 

Table

tab to select 

Table view

11.

Set the toggle switch at the right screen top to 
the center (off) position.  

12.

View table results:

Distance, Loss, and Reflectance are shown 
for each event.  

Tap the toggle switch to view All events or 
Failed events.

Figure 13: Trace view

Figure 14: Table view

Содержание 4100 Series

Страница 1: ...ion test Repeat until it passes Figure 2 Inspect Before You Connect Figure 1 Equipment Requirements 4100 series Expert OTDR This quick card describes how to connect to a fiber under test and use the EXPERT OTDR test application to configure test setups run tests and analyze results on a VIAVI T BERD MTS 2000 equipped with a 4100 series OTDR module T BERD MTS 2000 equipped with the following Fiber ...

Страница 2: ... Cable 3 Connect the Launch Cable to the OTDR port 4 If the interface to the FUT is a patch cord connect the patch cord to an optical coupler 5 Inspect the FUT connected to the coupler or OPP port and the fiber end face of the Launch Cable 6 Connect the Launch Cable to the coupler or OPP port Figure 5 Connecting to OPP LAUNCH TEST 1 Press the ON OFF button to start the test set 2 Press the Home bu...

Страница 3: ... width followed by an acquisition with a longer pulse width The first acquisition allows events at the beginning of the fiber to be detected more precisely Acq Time Select Realtime Auto or the desired time to sample the fiber Launch Cable Select and enter Length if you are using a Launch Cable Enter 20 meters or 66 feet for Viavi supplied 20 meter launch cables 3 Tap Alarms and configure pass fail...

Страница 4: ...to Event Line 5 View SmartLink results The FUT is displayed as a series of icons representing events front connector launch cable connectors splices bends etc and distances Swipe left or right to view additional icons on spans with more than 4 events The center of the display shows summary results for the entire span for each acquisition or wavelength Tap any event in the upper display to view det...

Страница 5: ...formation is shown in the upper display Tap 1 or 2 to select the acquisition wavelength or pulse width for results display Graphical results dB versus distance are shown in the center display A color coded Event table is shown in the lower display Swipe up and down to view all events 10 Tap the Table tab to select Table view 11 Set the toggle switch at the right screen top to the center off positi...

Страница 6: ... key 2 Enter Job Id Cable ID Fiber Number Locations and Direction The Job Id field identifies the Job and creates a folder by the same name Results are saved to this folder The Cable Id Fiber Id and Fiber Number fields determine the file name 3 Set Dir Naming to disk Job_Id Use the abc auto button to toggle between test entry and field entry 4 Set Save Mode to pdf 5 Tap Save 6 Tap to accept the de...

Отзывы: