Operation,
Screen Layout and Navigation
139187 / Rev. 500
RGS-2000NG TCAS Test Set Operation Manual
1-2-3
September 2021
Subject to Export Control. See Cover Page for details.
Page 127
3.5.4.5
Single Interrogation Test Measured Pulse Softkey Menu
The Measured Pulse Softkey Menu is used to define the settings for performing pulse measurements.
The contents of this menu depends on the type of pulse selected from the Measure Pulse Menu.
SCREEN SEQUE NCE:
Transponder Screen > Transponder Test Softkey > Test Mode: Single Interrogation > Measured Pulse
Softkey
F i g u r e 1 . 2 .3 - 1 1 0 T r a n s p o n d e r M e a s u r ed P u ls e S o f t k e y M e n u s
Screen Components
Descriptio n
Measured Pulse Menu
Selects pulse from which to obtain measurement data.
DF Data Frame Bit Field
This field defines the frame bit of the DF Data. Only applicable
to DF Frame Data Measured Pulse type.
Antenna Selection Toggle Switch
Selects the Antenna from which the pulse is measured (Top or
Bottom).
Level Field
Defines the scope trigger level. The trigger level can also be
adjusted using the Trigger Level Slider on the Main Display
Area.