2 CONNECTING THE EQUIPMENT
When connecting the equipment to the terminals provided on the main board, strip
the wires as little as possible (about 1/4”) to avoid electrical short circuits. Once the
wires are connected, run them through the electrical knockouts provided on the
bottom of the enclosure and use a watertight cable holders.
Additional holes made in
the enclosure will void the warranty.
Use adequate wire gauges when the Wireless module is
placed far from the Agri-Alert sub-modules.
2.1
Supply Inputs
2.1.1 Master Wireless Module
The Master Wireless module is generally powered by the 28V SBI of the AA9600 alarm
system. Make sure the battery and transformer boxes are properly connected to the
AA9600.
Do not connect an additional battery and transformer to the Wireless module
when the module is hooked up to a AA9600.
16VAC
SUPPLY INPUTS
14 15 16 17
BATTERY
+
REFER TO AA9600’s
WIRING DIAGRAM
BATTERY BOX
TRANSFO BOX
REFER TO AA9600’s
WIRING DIAGRAM
AGRI-ALERT 9600
4
5
6
7
SERIAL BUS
1
2
3
4
MASTER WIRELESS
MODULE
SERIAL BUS
1
2
3
4
16VAC
BATTERY
SUPPLY INPUTS
+
DO NOT
CONNECT A
BATTERY AND TRANSFORMER
TO THE WIRELESS MODULE
WHEN SUPPLIED BY THE
AGRI-ALERT 9600 SYSTEM
Figure 4 Master Wireless Module’s Supply