background image

400P-RV-AUTOMATIC ACCESSORIES:

45-Degree Extended Reach, Angled Chuck:

Open-ended air chuck allows reach into areas difficult to reach by hand. 

Connects to Tire Inflation Gun.

90-Degree Twist-on Chuck:

This open-ended air chuck can be attached to any inflation valve where there is limited clearance.

Primary Hose & Extension Hoses:

Dual hoses, with quick connect couplings.

Tire Inflation Gun:

Normally closed-ended chuck, (until lever is engaged) all air chucks attach to the Tire Inflation Gun 

with quick connect couplings.

SAFETY PRECAUTIONS:

1. Always inflate tires to manufacturer’s recommended tire pressures. Exercise extreme caution

when driving with aired-down tires. Reinflate tires before high-speed roadway travel.

2. Never exceed 20 M.P.H. when driving with partially inflated tires.

3. Never make sharp turns while driving with reduced tire pressure.

4. Re-inflate tires before high speed traveling onto roadways.

5. Use heat-resistant, minimum 200 PSI-rated working pressure extension hose.

Do not use aftermarket hoses with less than 200 PSI working pressure. Some aftermarket hoses

may not be suitable for use with this air compressor due to heat and pressure typically generated

by this type of air compressors.

CAUTION:

 Never touch the air compressor or fittings connected to the air compressor other than 

the ON/OFF switch with bare hands during or immediately after use. The extension hose and fittings 

connected extension hose will become very HOT during and after use. If necessary, wear heat 

resistant gloves to remove hose from the compressor quick connect stud.

MAINTENANCE & REPAIRS:

Your air compressor is equipped with permanently lubricated, maintenance-free motor. 

 

Never try to lubricate the compressor.  Regularly clean dust and dirt from compressor cooling fins 

and motor housing.  All repairs should be performed by Manufacturer or Manufacturer authorized 

service agencies only.

400P-RVS AUTOMATIC PORTABLE COMPRESSOR

USER MANUAL

Содержание 40044

Страница 1: ...OMPRESSOR HEAVYWEIGHT SERIES PART NO 40044 IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL ...

Страница 2: ...r explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or attachments without first determining maximum air pressure for that tool or attachment Never point any air nozzle or air sprayer toward another person or an...

Страница 3: ...of 155 PSI 5 During inflation of tire pressures between 130 PSI to 155 PSI if you stop inflation the compressor may not restart This is completely normal since inline pressure is greater than cut on pressure of the pressure switch and less than cut off pressure of the pressure switch To restart compressor deflate tire pressure to below 130 PSI reconnect tire chuck to tire valve stem and resume tir...

Страница 4: ... injury NOTE Your air compressor is equipped with a pressure switch cut on at 130 PSI cut off at 155 PSI This feature is designed to protect the air compressor from over pressure causing permanent damage to your air compressor The pressure switch automatically turns off the motor when the internal pressure of the air compressor reaches the factory set cut off pressure of 155 PSI and restarts when ...

Страница 5: ... before high speed traveling onto roadways 5 Use heat resistant minimum 200 PSI rated working pressure extension hose Do not use aftermarket hoses with less than 200 PSI working pressure Some aftermarket hoses may not be suitable for use with this air compressor due to heat and pressure typically generated by this type of air compressors CAUTION Never touch the air compressor or fittings connected...

Страница 6: ...e red plug from compressor s air inlet port 3 Install inlet air filter onto compressor s air inlet port Thread tape Not Recommended 4 Hand tighten inlet air filter IMPORTANT For optimal compressor performance replace filter element periodically Clogged filter will drastically reduce compressor flow rate and performance 400P RVS AUTOMATIC PORTABLE COMPRESSOR USER MANUAL ...

Страница 7: ... cuts out repeatedly 1 Lack of proper ventilation or ambient temperature is too high 2 Compressor valves failed 1 Move compressor to well ventilated area or area with lower ambient temperature 2 Replace compressor Excessive knocking or rattling 1 Worn bearing on eccentric or motor shaft 2 Cylinder or piston ring is worn 1 Service or replace compressor Compressor air flow lower than normal or canno...

Страница 8: ...ithout the prior express written consent of VIAIR VIAIR does not make any representations warranties or guarantees express or implied as to the accuracy or completeness of the Manual Users must be aware that updates and amendments will be made from time to time to the Manual It is the user s responsibility to determine whether there have been any such updates or amendments Neither VIAIR nor any of...

Отзывы: