3
Dear Customer,
Thank you for purchasing a universal boiler HERCULES U 32 and thus showing your confidence in the company VIADRUS a.s.
For the correct way of handling your new boiler, please read the instructions for its use, especially the Chap. no. 7. – Boiler operation by user,
the Chap. no. 8 - Maintenance and the Chap. No. 9 - Important warnings. Please follow further information, ensuring trouble-free boiler
operation to both your and our satisfaction.
The boiler HERCULES U 32 is cast-iron sectional gasification boiler designed to burn:
HERCULES U32 D
fuel: hard wood
HERCULES U32 B
fuel: lignite
HERCULES U32
fuel: hard coal
Burning of other materials (e.g. plastic) is forbidden.
1
Boiler Use and Advantages
The boiler HERCULES U 32 meets the requirements for heating of houses, shops, etc.
The boiler is manufactured as hot water boiler with natural and forced circulation of hot water and working overpressure up to 400 kPa (4 bar).
Before dispatch it is checked for tightness with the test pressure of 800 kPa (8 bar).
The boiler is designed for heating in both closed and open heating systems.
The Boiler Advantages:
1. High service life of cast iron exchanger and all other parts due to the quality of the materials used.
2. Long-term proven design.
3. Sophisticated manufacturing technology on the automatic forming lines with consistent and approved quality of the production process (ISO
9001, ISO 14 001).
4. Combustion efficiency 86,5 - 90 %.
5. Low fuel consumption.
6. Simple operation and maintenance.
2
Technical parameters of the boiler
Tab.
№
. 1
Dimensions and technical parameters of the boiler
Number of sections
5
6
7
Combustion chamber volume
dm
3
32
39
51
Water content
l
40,5
46,5
52,5
Weight
kg
348
410
472
Combustion chamber depth
mm
280
370
480
Flue socket diameter
mm
156
156
156
Boiler dimensions: – height x width
mm
1240 x 683
1240x683
1240x683
– depth L
mm
881
992
1103
Filling hole dimensions
mm
310x236
310 x 236
310 x 236
Maximum water operating pressure
kPa (bar)
400 (4)
400 (4)
400 (4)
Minimum water operating pressure
kPa (bar)
50 (0,5)
50 (0,5)
50 (0,5)
Test water overpressure
kPa (bar)
800 (8)
800 (8)
800 (8)
Hydraulic loss
-
see Fig. 1
see Fig. 1
see Fig. 1
Input water minimum temperature
°C
50
50
50
Heating water recommended operating
temperature
°C
60 – 80
60 – 80
60 – 80
Noise level
dB
< 65
< 65
< 65
Boiler connections: – heating water
2“
2“
2“
– return water
2“
2“
2“
Temperature of cooling water for the device
for removing excess heat
°C
5 – 20
5 – 20
5 – 20
Overpressure of cooling water for the
device for removing excess heat
kPa (bar)
200 – 600 (2 - 6)
200 – 600 (2 - 6)
200 – 600 (2 - 6)
Tab.
№
. 2
HERCULES U32 D technical parameters - fuel: hard wood
fuel moisture max. 20 %
calorific power: 14 – 18 MJ. kg
-1
Number of sections
5
6
7
Boiler class in accordance with EN 303 – 5
-
3
3
3
Rated power
kW
15
19
22
Fuel consumption
kg/h
3,7
4,8
5,5
Max. fuel mass in the filling chamber
kg
12
14
16
Flue gas temperature at rated output
°C
130 - 170
130 - 170
130 - 170
Flue gas mass flow at rated power
kg/sec
0,01
0,0137
0,015
Chimney draught
mbar
0,18
0,20
0,22
Burning time
hours
min. 2
min. 2
min. 2
Efficiency
%
88,9
88,3
88,0
Energy efficiency class
A+
A+
A+
Energy efficiency index
116
115
114
Season energy efficiency
%
79
78
78