IMPORTANT NOTICES!  

 
1.  It is prohibited to connect the storage tanks unfulfilled with water. 
2.  It is forbidden to operate the inner HWS heater and the external heating water tank without a functioning 

safety valve (the function of valve must be checked every 14 days –by turning the valve to the left and to 
the  right  so  that  water  is  flowing  out  from  the  side  outlet  draining  the  water.  Then  turn  the  valve  in  the 
opposite  direction  until  it  snaps  in  the  initial  position  and  push  it  into  the  valve  body.  If  no  water  leaks 
during  the  valve  turning  it  means  that  the  valve  is  not  functional.  If  after  turning  the  valve  and  after  its 
return  to  the  original  position  the  water  permanently  leaks  this  means  that  the  cone  of  valve  is  dirty 
therefore  it  should  be  flushed  several  times  by  opening  the  drain(outlet)  by  turning  the  valve. 
ATTENTION  –  possible  escape  of  hot  water.  The  company  does  not  assume  the  responsibility  for  the 
safety  valve  malfunction  which  is  caused  by  faulty  assembly  of  valve  and  errors  in  installation  e.g. 
reduction valve missing in the installation of cold water inlet. Maximal pressure when the safety valve is  
the  fully  open  must  not  exceed  0.67  MPa  for  the  HWS  tank,  but  in  case  of  heating  water  the  pressure 
must not exceed 0,35 MPa  when the safety valve is  the fully open and the system is closed

3.  Between the safety  valve and storage tank there must not be  installed any other  element (device) - for 

example, shut-off valve, water seal, etc. 

4.  The repair method is specified by the manufacturer. 
5.  By the proper security cooperating with the storage tank of boiler it is also ensured the proper security of 

spiral in the storage tank. 

6.  At least once a year the company must be charged with rinsing the tank to remove sediments.  
7.  Plastic  pipes  must  not  be  used  for  connection  of  storage  tanks  because  they  are  not  adapted  to 

temperatures of 95 ° C and pressure of 0.7 MPa. 

8.  Storage tanks must be installed so that  the free  access (e.g. for the purpose of  maintenance, repair or 

replacement) is ensured. 

9.  Replace  the  magnesium  anode  in  HWS  tank  at  least  once  every  18  months  (it  is  necessary  to  keep 

proof of purchase anode). Regular replacement is a condition of the tank warranty validity (this regards 
the enamelled tank). 

10.  To prolong the service life of the tank and ensure proper functioning of the safety valve is necessary to 

use filters for catching impurities. 

11.  If the tanks are operated in a very aggressive environment (e.g. cowshed), it is necessary to purchase a 

product which is specially adapted to operate in such environment (the parts that might be damaged by 
rapid corrosion are adjusted by the manufacturer and an appropriate chemical finish is applied to them) 

12.  It is prohibited to prevent water from dripping from the safety valve – don’t obstruct the drainage hole of 

the  safety  valve!  If  the  water  during  operation  leaks  from  the  valve  continuously  it  signals  that  the 
pressure in installation is too high or the valve is not  functioning properly. Outfall of water drained from 
the valve must be directed downward. Under the valve place a funnel for water drain off. Also a hose can 
be  put  on  the  outfall  and  it  will  drain  off  water  when  the  valve  is  open.  This  hose  must  be  resistant  to 
temperatures of +80 ° C, its inside diameter is 9 mm and maximum length 1.2 m. The hose must be led 
to  the  drainage  with  gradient  min.  3%  and  in  an  environment  in  which  the  temperature  does  not  drop 
below 0 ° C. The hose must be ensured against reduction of inside diameter and its end must be visible 
(for the check of valve function).  

13.  In the event of failure of a product it is necessary to inform the company from which the storage tank 

was  purchased.  It  is  necessary  to  retain  the  proof  of  storage  tank  purchase  for  the  purpose  of 
inspection carried out by the customer service. The exchange of seal, exchange of magnesium anodes, 
etc. are not included in the number of repairs.. 

14.  The  certificate  of  warranty  is  the  basis  of  a  warranty  repair.  The  certificate  of  warranty  must  complete, 

filled out properly and without any corrections (retain it for the entire duration of the warranty). 

15.  The matters not regulated by the above conditions will be dealt with according to Civil Code. 
16.  The manufacturer is not responsible for any irregularity or expense caused by the removal (demounting)  
17. The manufacturer reserves the right to make any modifications without notice. 
 

Содержание AkuCOMBI 1000/200 L

Страница 1: ...Hercules U26 Návod k obsluze STORAGE TANKS OPERATING AND INSTALLATION MANUAL AkuCOMBI 500 160 L AkuCOMBI 600 200 L AkuCOMBI 800 200 L AkuCOMBI 1000 200 L ...

Страница 2: ...age 1 Description of construction 3 2 Installation of the storage tank 3 3 Type defects their causes and remedies 3 4 IMPORTANT NOTICES 4 5 Instructions for product disposal after its service life expiration 5 6 Guarantee 5 ...

Страница 3: ... maintenance with pressure not exceeding 0 6 MPa but the minimal pressure must not be lower than 0 1 MPa approx l atm In the event that water pressure in the water main exceeds 0 6 MPa it must be reduced using a reduction valve n the cold water inlet pipe there must be installed a safety valve The drain valve of the safety valve always must be left open and be in contact with the atmosphere It is ...

Страница 4: ...s it is necessary to keep proof of purchase anode Regular replacement is a condition of the tank warranty validity this regards the enamelled tank 10 To prolong the service life of the tank and ensure proper functioning of the safety valve is necessary to use filters for catching impurities 11 If the tanks are operated in a very aggressive environment e g cowshed it is necessary to purchase a prod...

Страница 5: ...Guarantee Guarantee of an enamel storage tank is 36 months The other parts 24 months The guarantee includes the above period but the maximum the period of warranty plus 12 months from the date of manufacture The manufacturer for the validity of his guarantee requires To inspect storage tanks regularly once a year Only an authorized service organization is qualified to exercise the inspections To d...

Страница 6: ...6 AkuCOMBI 500 160 L AkuCOMBI 600 200 L AkuCOMBI 800 200 L AkuCOMBI 1000 200 L GS1 GS2 GS3 GS4 GS5 GS6 GS7 0 GS8 GS9 GS10 L GS11 Air release valve G 1 2 ...

Страница 7: ...T G 1 2 CIRCULATION G 3 4 10 COLD WATER INLET G 3 4 10 REVERSE OF SPIRAL G 3 4 10 SENSOR PROTECTION R 1 2 12 HWS OUTLET G 3 4 10 VENT G 1 2 SUPPLY G 3 4 CIRCULATION G 3 4 HWS G 3 4 REVERSE G 3 4 COLD WATER G 3 4 MAGNESIUM ANODE SENSOR PROTECTION ...

Страница 8: ...inlet GS7 mm 1360 Height of other source connection return GS8 mm 360 Height of other source connection inlet GS9 mm 710 Height of other source connection return GS10 mm 1010 Height of other source connection inlet GS11 mm 1360 Height of equipment L mm 1730 Tank diameter without insulation Ø mm 700 Diameter with insulation Ø mm 900 Insulation made of hardened polyurethane foam mm 100 External shel...

Страница 9: ...ion CH GS6 mm 1335 Height of CH connection inlet GS7 mm 1560 Height of other source connection return GS8 mm 360 Height of other source connection inlet GS9 mm 760 Height of other source connection return GS10 mm 1160 Height of other source connection inlet GS11 mm 1560 Height of equipment L mm 1920 Tank diameter without insulation Ø mm 700 Diameter with insulation Ø mm 900 Insulation made of hard...

Страница 10: ...inlet GS7 mm 1220 Height of other source connection return GS8 mm 430 Height of other source connection inlet GS9 mm 750 Height of other source connection return GS10 mm 1000 Height of other source connection inlet GS11 mm 1320 Height of equipment L mm 2000 Tank diameter without insulation Ø mm 900 Diameter with insulation Ø mm 1100 Insulation made of hardened polyurethane foam mm 100 External she...

Страница 11: ...nlet GS7 mm 1225 Height of other source connection return GS8 mm 430 Height of other source connection inlet GS9 mm 830 Height of other source connection return GS10 mm 1120 Height of other source connection inlet GS11 mm 1520 Height of equipment L mm 2000 Tank diameter without insulation Ø mm 900 Diameter with insulation Ø mm 1100 Insulation made of hardened polyurethane foam mm 100 External shel...

Страница 12: ...12 ...

Страница 13: ...n must be carried out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confirms th...

Страница 14: ...arranty for the customer user Record of the carried out warranty and post warranty repairs and regular annual checks of the product Date of record Carried out activity Contractual service organization signature stamp Signature of customer ...

Страница 15: ... Into operation must be carried out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The us...

Страница 16: ...16 ...

Страница 17: ...eration must be carried out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confi...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...20 Date of revision 46 2012 GB ...