Intended for the manufacturer  

VIADRUS a.s., 
Bezru

č

ova 300 

735 81 Bohumín 

 

Certificate of warranty and Certificate of quality and completeness of 

the storage tank: 

AkuCOMBI 500/160 L 
AkuCOMBI 600/200 L 
AkuCOMBI 800/200 L 

AkuCOMBI 1000/200 L 

 
 
Serial number of the storage tank 

………………………………………………………………………………. 

 
 
User (surname, first name)  

………………………………………………………………………………. 

 
 
Address (street, city, zip code)  

………………………………………………………………………………. 

 
 
Phone / Fax 

………………………………………………………………………………. 

 
 
Overpressure in the inlet water pipe 

 ................................... kPa 

 
 
Conditions of the validity of the warranty:  

 

Installation  of  the  storage  tank  must  be  carried  out  according  to  "

 

Operating  and  installation 

manual for storage tanks” by a professional firm  

 

Putting  Into  operation  must  be  carried  out  according  to  "Operating  and  installation  manual  for 
storage tanks” by a contractual service organization accredited by the manufacturer  

 

The faults must be removed by a contractual service organization accredited by the manufacturer  

 
The completeness of the supplied storage tank is guaranteed by the seller  

The certificate of warranty is void if not filled out. 
 
The user confirms that:  

 

he has received the "Operating and Installation manual"  

 

he has been acquainted with the  operation and maintenance of the storage tank 

 

 
 
 

…………………………………….. 

 
 
 

…………………………………….. 

 
 
 

…………………………………….. 

Production date 

Stamp of the manufacturer 

Checked by: (signature) 

 
 
 

…………………………………….. 

 
 
 

……………………………………... 

 
 
 

…………………………………….. 

Date of installation 

Installation company 

(stamp, signature) 

Signature of user 

 
 
 

……………………………………. 

 
 
 

…………………………………….. 

 
 
 

…………………………………….. 

Date of putting into operation 

Contractual service organization 

(stamp, signature) 

Signature of user 

Содержание AkuCOMBI 1000/200 L

Страница 1: ...Hercules U26 Návod k obsluze STORAGE TANKS OPERATING AND INSTALLATION MANUAL AkuCOMBI 500 160 L AkuCOMBI 600 200 L AkuCOMBI 800 200 L AkuCOMBI 1000 200 L ...

Страница 2: ...age 1 Description of construction 3 2 Installation of the storage tank 3 3 Type defects their causes and remedies 3 4 IMPORTANT NOTICES 4 5 Instructions for product disposal after its service life expiration 5 6 Guarantee 5 ...

Страница 3: ... maintenance with pressure not exceeding 0 6 MPa but the minimal pressure must not be lower than 0 1 MPa approx l atm In the event that water pressure in the water main exceeds 0 6 MPa it must be reduced using a reduction valve n the cold water inlet pipe there must be installed a safety valve The drain valve of the safety valve always must be left open and be in contact with the atmosphere It is ...

Страница 4: ...s it is necessary to keep proof of purchase anode Regular replacement is a condition of the tank warranty validity this regards the enamelled tank 10 To prolong the service life of the tank and ensure proper functioning of the safety valve is necessary to use filters for catching impurities 11 If the tanks are operated in a very aggressive environment e g cowshed it is necessary to purchase a prod...

Страница 5: ...Guarantee Guarantee of an enamel storage tank is 36 months The other parts 24 months The guarantee includes the above period but the maximum the period of warranty plus 12 months from the date of manufacture The manufacturer for the validity of his guarantee requires To inspect storage tanks regularly once a year Only an authorized service organization is qualified to exercise the inspections To d...

Страница 6: ...6 AkuCOMBI 500 160 L AkuCOMBI 600 200 L AkuCOMBI 800 200 L AkuCOMBI 1000 200 L GS1 GS2 GS3 GS4 GS5 GS6 GS7 0 GS8 GS9 GS10 L GS11 Air release valve G 1 2 ...

Страница 7: ...T G 1 2 CIRCULATION G 3 4 10 COLD WATER INLET G 3 4 10 REVERSE OF SPIRAL G 3 4 10 SENSOR PROTECTION R 1 2 12 HWS OUTLET G 3 4 10 VENT G 1 2 SUPPLY G 3 4 CIRCULATION G 3 4 HWS G 3 4 REVERSE G 3 4 COLD WATER G 3 4 MAGNESIUM ANODE SENSOR PROTECTION ...

Страница 8: ...inlet GS7 mm 1360 Height of other source connection return GS8 mm 360 Height of other source connection inlet GS9 mm 710 Height of other source connection return GS10 mm 1010 Height of other source connection inlet GS11 mm 1360 Height of equipment L mm 1730 Tank diameter without insulation Ø mm 700 Diameter with insulation Ø mm 900 Insulation made of hardened polyurethane foam mm 100 External shel...

Страница 9: ...ion CH GS6 mm 1335 Height of CH connection inlet GS7 mm 1560 Height of other source connection return GS8 mm 360 Height of other source connection inlet GS9 mm 760 Height of other source connection return GS10 mm 1160 Height of other source connection inlet GS11 mm 1560 Height of equipment L mm 1920 Tank diameter without insulation Ø mm 700 Diameter with insulation Ø mm 900 Insulation made of hard...

Страница 10: ...inlet GS7 mm 1220 Height of other source connection return GS8 mm 430 Height of other source connection inlet GS9 mm 750 Height of other source connection return GS10 mm 1000 Height of other source connection inlet GS11 mm 1320 Height of equipment L mm 2000 Tank diameter without insulation Ø mm 900 Diameter with insulation Ø mm 1100 Insulation made of hardened polyurethane foam mm 100 External she...

Страница 11: ...nlet GS7 mm 1225 Height of other source connection return GS8 mm 430 Height of other source connection inlet GS9 mm 830 Height of other source connection return GS10 mm 1120 Height of other source connection inlet GS11 mm 1520 Height of equipment L mm 2000 Tank diameter without insulation Ø mm 900 Diameter with insulation Ø mm 1100 Insulation made of hardened polyurethane foam mm 100 External shel...

Страница 12: ...12 ...

Страница 13: ...n must be carried out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confirms th...

Страница 14: ...arranty for the customer user Record of the carried out warranty and post warranty repairs and regular annual checks of the product Date of record Carried out activity Contractual service organization signature stamp Signature of customer ...

Страница 15: ... Into operation must be carried out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The us...

Страница 16: ...16 ...

Страница 17: ...eration must be carried out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confi...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...20 Date of revision 46 2012 GB ...

Отзывы: