Cautions 

 

Do not drop the device or subject it to physical shock, and do not expose it to high 
electromagnetism radiation. Avoid the equipment installation on vibrations surface or 
places subject to shock (ignorance can cause equipment damage).

 

Do not place the device in extremely hot (refer to the specification of the device for 
the detailed operating temperature), cold, dusty or damp locations, and do not 
expose it to high electromagnetic radiation.

 

The device cover for indoor use shall be kept from rain and moisture.

 

Exposing the equipment to direct sun light, low ventilation or heat source such as 
heater or radiator is forbidden (ignorance can cause fire danger).

 

Do not aim the device at the sun or extra bright places. A blooming or smear may 
occur otherwise (which is not a malfunction however), and affecting the endurance of 
sensor at the same time.

 

Please use the provided glove when open up the device cover, avoid direct contact 
with the device cover, because the acidic sweat of the fingers may erode the surface 
coating of the device cover.

 

Please use a soft and dry cloth when clean inside and outside surfaces of the device 
cover, do not use alkaline detergents.

 

Please keep all wrappers after unpack them for future use. In case of any failure 
occurred, you need to return the device to the factory with the original wrapper. 
Transportation without the original wrapper may result in damage on the device and 
lead to additional costs.

 

Improper use or replacement of the battery may result in hazard of explosion. 
Replace with the same or equivalent type only. Dispose of used batteries according to 
the instructions provided by the battery  manufacturer.

Содержание VZ-IP-INTPRO

Страница 1: ...Video Intercom Door Station Quick Start Guide...

Страница 2: ...ER ATTACK VIRUS INSPECTION OR OTHER INTERNET SECURITY RISKS HOWEVER OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED SURVEILLANCE LAWS VARY BY JURISDICTION PLEASE CHECK ALL RELEVANT LAWS...

Страница 3: ...the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on...

Страница 4: ...t documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery...

Страница 5: ...al region Please use the power adapter which is provided by normal company The power consumption cannot be less than the required value Do not connect several devices to one power adapter as adapter o...

Страница 6: ...a bright places A blooming or smear may occur otherwise which is not a malfunction however and affecting the endurance of sensor at the same time Please use the provided glove when open up the device...

Страница 7: ...Alarm Device Output Wiring 10 3 Installation 11 3 1 Installation of Door Station 11 3 1 1 Gang Box 11 3 1 2 Wall Mounting with Gang Box 12 4 Before You Start 14 5 Local Operation 15 5 1 Keys Descript...

Страница 8: ...oor Station Quick Start Guide 1 1 Appearance 1 1 Appearance of Door Station Figure 1 1 Front View Figure 1 2 Rear View Table 1 1 Descriptions Keys No Description 1 Low Illumination Supplement Light 2...

Страница 9: ...Video Intercom Door Station Quick Start Guide 2 No Description 3 Loudspeaker 4 LCD Display Screen 5 Card Induction Area 6 Keypad 7 Call Button 8 Call Center Key 9 Microphone 10 TAMPER...

Страница 10: ...Video Intercom Door Station Quick Start Guide 3 2 Terminal and Wiring 2 1 Terminal Description Figure 2 1 Terminals and Interfaces...

Страница 11: ...C 12V DC 12V Power Supply Input READER A1 12V Power Supply Output A2 GND Grounding A3 W1 Data Input Interface Wiegand Card Reader Data1 A4 W0 Data Input Interface Wiegand Card Reader Data0 A5 BZ Card...

Страница 12: ...al Port Debugging Power Supply DOOR C1 12V Power Supply Output C2 GND Grounding C3 NC2 Door Lock Relay Output NC C4 COM2 Grounding Signal C5 NO2 Door Lock Relay Output NO C6 NC1 Door Lock Relay Output...

Страница 13: ...iring Terminal NC1 COM1 is set as default for accessing magnetic lock electric bolt terminal NO1 COM1 is set as default for accessing electric strike Toconnect electric lock in terminal NO2 COM2 NC2 i...

Страница 14: ...ring Door Magnetic Wiring Figure 2 3 Door Magnetic Wiring To connect the door magnetic it is required to set the output of terminal AI2 to be door magnetic with Batch Configuration Tool or VEZPRO 2 2...

Страница 15: ...hen the card reader is power on please reboot the card reader after configuring the DIPswitch The DIP switch description is shown in the following table No Description How to Configure 1 4 Set the RS...

Страница 16: ...2 5 External Elevator Controller Wiring You can connect the door station to the elevator controller via RS 485 interface There are 4 groups of RS 485 interfaces on the elevator controller group A grou...

Страница 17: ...r Station Quick Start Guide 10 2 2 6 Alarm Device Input Wiring Alarm Device Input Wiring Figure 2 7 Alarm Device Input Wiring Alarm Device Output Wiring Alarm Device Output Wiring Figure 2 8 Alarm Dev...

Страница 18: ...sure your power supply matches your door station Make sure all the related equipment is power off during the installation Check the product specification for the installation environment 3 1 Installa...

Страница 19: ...e hole should be larger than that of the gang box The suggested size of hole is 343 5 length 113 5 width 55 5 depth mm 2 Insert the gang box into the hole and fix it with 4 PA4screws Screw Screw Figur...

Страница 20: ...ercom Door Station Quick Start Guide 13 5 Put the door station into the gang box Figure 3 3 Install the Door Station 6 Fix the door station to the gang box with 4 crews Figure 3 4 Tighten the Screws o...

Страница 21: ...RO refer to 6 1 Activating Device Remotely To activate the device locally refer to 5 2 Activating Device To configure the key parameters of device on the user interface of door station you are require...

Страница 22: ...Descriptions 1 Key Description Numeric Key 2 Numeric Key 4 Numeric Key 6 Numeric Key 8 Call Key When calling residents or center Confirm Return Delete 5 2 Activating Device You cannot use the door sta...

Страница 23: ...4 Press the key to complete the activation Key Description Key Description 1 1 6 6mnoMNO 2 2abcABC 7 7pqrsPQRS 3 3defDEF 8 8tuvTUV 4 4ghiGHI 9 9wxyzWXYZ 5 5jklJKL 0 0 STRONG PASSWORD RECOMMENDED We hi...

Страница 24: ...e key for 2s to enter the admin password interface 2 Enter the admin password and press the key Figure 5 3 Admin Password Interface The default admin password is 888999 2 Enter the network parameters...

Страница 25: ...sword admin password and card activation password Configuration Password It is necessary when you want to configure parameters of the door station such as IP parameters door station No system type and...

Страница 26: ...admin password is 888999 2 Press the numeric keys 4 and 6 to switch to the password settings interface Figure 5 7 Password Settings Interface Changing Configuration Password Steps 1 On the password s...

Страница 27: ...ation Password Changing Interface 2 Enter the old password and the new password and confirm the new one 1 Move the cursor to parameters to be configured 2 Press the key to enter or exit the editing mo...

Страница 28: ...y inputting the password is only available in the network intercom system Steps 1 Enter the key and the Room No 2 Enter the password and the key The password varies according to different rooms The de...

Страница 29: ...ice Activation via Batch Configuration Tool and Activation via VEZPRO are supported Here take activation via Batch Configuration Tool as example to introduce the device activation Please refer to the...

Страница 30: ...via batch configuration tool as example Steps 1 Select an online activated device and click the Edit NET Parameters button Figure 6 3 Clicking Edit NET Parameters Button 2 Change the device IP addres...

Страница 31: ...to configure the device remotely 3 ways for adding the device are supported adding active online devices within your subnet adding device by IP address and adding device by IP segment Here take addin...

Страница 32: ...t for configuration If you add devices in batch please make sure selected devices have the same user name and password 6 3 2 Adding by IP Address Purpose You can add the device by entering IP address...

Страница 33: ...ng by IP Address 4 Click the OK button to add the device to the device list You cannot add the device s to the device list if the user name and password are not identical When you add devices by IP Ad...

Страница 34: ...e between two devices is recommended to be longer than 10 meters Here devices refer to indoor station outdoor station and master station Wiring Cables Cable Specification Power Cord of Door Station RV...