05
Cleaning
• If the shell is soiled, wipe it with a flexible cloth.
• After each use of the main engine tank, clean the residual fouling with
clean water, and at least burn the cleaning reagent (citric acid)
recommended by our company every month.
• Add 1.0L water and 2 tablespoons citric acid into the tank of the main
engine, without covering the head component, boil water for about 30
minutes after electrifying, then pour out the water and use it to clear
Rinse with water. If scale cannot be removed at one time, the above
method can be repeated for cleaning.
• If it is a plastic outlet, it is recommended to replace it every 2 to 3
months.
• Head assembly shakes or water overflows during water boiling
1. The water in the main engine tank exceeds the maximum water level
mark.
2. If the head assembly is not installed properly with the host, it needs to
be taken out and placed on the host again, and the placement effect
should be properly felt by hand.
3. The sealing ring of the head assembly is not installed properly, so it
needs to be taken out and reinstalled.
4. The outlet nozzle is blocked by dirt deposition, so it is necessary to
replace the outlet nozzle or clean the outlet nozzle.
Common Exceptions and Handing
• No distilled water dripping
1. The host power supply and head power socket are not plugged in
place, please check and plug again.
2. The start button is not pressed (the red indicator light is not on).
3. There is no water in the main engine tank.
• Insufficient distilled water is produced each time
1. The water in the main engine tank does not reach the maximum water
level mark.
2. If the sealing ring of the head assembly is missing or poorly sealed,
check and reinstall the sealing ring or replace it with a new one.
3. There is no water in the main engine tank.
4. The water outlet nozzle of the machine head is poorly installed and
needs to be removed and reinstalled.
will enter the insulation state, when heated to 83 ℃, the insulation will
last for 2 hours and 10 minutes. When setting the temperature, you can
directly press the "+" and "-" keys to adjust the required temperature
value. The machine will enter the heating state 3 seconds after stopping
the setting.