DGT / DGT60 / DGTQ / DGTP
27
3)
Select the number of the connected cells
Select number of scales (in other words, the number of channels, from 1 to 4) connected to the indicator:
SEtuP >> ConFiG >> nChan
>> 1..4
and press
.
4)
Select the cell to be calibrated
Select the scale to be calibrated (in other words the channel number, from1 to 4):
SEtuP >> ConFiG >> Chan
>> 1..4
and press
.
5)
Select the step
SEtuP >> ConFiG >> CALib
and press
.
6)
Setting Total Capacity or 1st Range
Select the "rAnGE1" step and press
;
Set the total capacity of the scale or the first range in case of multirange functioning.
The keys take on the following functionalities:
ZERO
Decreases the selected digit (blinking).
TARE
Increases the selected digit (blinking).
MODE
Selects the digit to be modified (blinking), from left to right.
C
Quickly zeros the displayed value.
7)
Setting of the 2nd Range capacity
Select the "rAnGE2" step (only in case of dual range scale) and press
;
Set the capacity of the second range and press
.
8)
Minimum Division
Select the "diV" step and press
;
Set the scale’s minimum division or the first range in case of dual range and press
(selectable values:
1, 2, 5, 10, 20, 50).
Note:
the settable division refers to the FIRST RANGE. With the second range the following division is set.
For example, by setting diV=2 , the second range will have diV=5
(!) 1
9)
Number of Decimal digits
Select the
"
dECi" step and press
;
The selectable values are 1.0 (one decimal), 1.00 (two decimals), 1.000 (three decimals), 100000 (no
decimal); confirm with
.
(!) 1.000
10)
Unit of Measure
Select the "u.M."
and press
.
Set the unit of measure (g, Lb, t, kg) and press
.
(!) kg
11)
Select the "CALib.P" step and press
.
12)
Select the "ntP" step and press
.
13)
Nr. of Calibration points
Set the number of points with the
ZERO
or
TARE
keys on which one wants to make the calibration (from 1 to
3, with 1 one will make the zero point and a weight point) and press
.
14)
Acquisition of Scale Zero
Select the "tP0" step (scale zero point): unload the scale and wait a few seconds; then press
.
15)
Setting of 1st Sample Weight
Select the "ddt1" step (setting of first sample weight); press
, enter the weight value and confirm with
.
16)
Acquisition of 1st Sample Weight
Select the "tP1" step (acquisition of first sample weight): put the weight on the scale, wait a few seconds and
press
.
17)
If a calibration point had been set
, once the weight acquisition has been made, the display shows for an
instant the value of the internal divisions and then the "ntP" step (or "EqUAL" for the procedure of calibration
4.2).
18)
If there are more calibration points, repeat the operations for the points "ddt2", "tP2", "ddt3", "tP3".
Once the weight acquisition is made, the display shows for an instant the value of the internal divisions and
then the "ntP" step (or "EqUAL" for the calibration procedure 4.2).
19)
If a single scale is connected to the instrument
(nChan
= 1) >>
Go to point 19)
If there are various scales connected to the instrument
(nChan
> 1) >>
Repeat the calibration procedure
for each scale, starting from point 3) in order to select the scale to be calibrated (go through again the steps
Содержание DGT
Страница 1: ...WEIGHT INDICATORS DGT DGT60 DGTQ and DGTP Technical Manual DGT_DGT60_DGTQ_DGTP_06 01_09 11_EN_T...
Страница 65: ...DGT DGT60 DGTQ DGTP 65 11 CONNECTION SCHEMES 11 1 DGT4 DGT60 DGT4 AN MOTHERBOARD I O BOOT J 1...
Страница 68: ...DGT DGT60 DGTQ DGTP 68 11 2 DGT4 PB MOTHERBOARD I O BOOT J 1...
Страница 71: ...DGT DGT60 DGTQ DGTP 71 11 3 DGTQ DGTQ AN BOARDS...
Страница 72: ...DGT DGT60 DGTQ DGTP 72 I O BOOT J1 J2 CAL...
Страница 76: ...DGT DGT60 DGTQ DGTP 76 11 4 DGTQ PB BOARDS...
Страница 77: ...DGT DGT60 DGTQ DGTP 77...
Страница 81: ...DGT DGT60 DGTQ DGTP 81 11 5 DGTP DGTP AN DGTP PB MOTHERBOARD...