background image

Table of Contents

 

Rev. 5.7.2019 

TCD MANUAL 

Table of Contents

 

Copyright 2019 Vestil Manufacturing Co. 

Page 1 of 20 

TCD -Series Trash Can Dumpers 

Instruction Manual

 

Receiving instructions: 

After delivery,  remove the packaging from the product. Inspect the product closely to determine whether it 

sustained damage during transport. If damage is discovered, record a complete description of it on the bill of lading. 

If the product is undamaged, discard the packaging.

 

NOTE:

 

The end-user is solely responsible for confirming that product design, use, and maintenance comply with laws, 

regulations, codes, and mandatory standards applied where the product is used.

 

Replacement Parts and Technical Service: 

  For answers to questions not addressed in these instructions and to order replacement parts, labels, and 

accessories, call our Technical Service and Parts Department at (260) 665-7586. The department can also be 

contacted online at 

http://www.vestilmfg.com/parts_info.htm

. 

 

 

Table of Contents 

TCD-M Specifications

.………..…………….………………………………………………………………………..…. 

2

 

TCD-U Specifications

………………………………………………………………………………………………… 

3

 

Signal Words

……….……................................................................................................................................ 

4

 

Hazards

…………………..……………………………………………………………………………………………….

4

 

Exploded Parts Diagrams and Bills of Materials

…..………………………………………………………....

5

6

7

8

 

*

Power Unit Operation

…………………………………………..…………………………………………….......... 

9

*

Cleaning the Lowering Solenoid Valve

……………..………………………………………………………

..

….

9

 – 

10

*

Bleeding Air from the Hydraulic System

…………………………………………………………………

..

………… 

10

*

Hydraulic Circuit Diagram

………………………………………………………………………………………

..

…… 

10

*

Electric Circuit Diagrams

……………………………………………………………………………………

..

….

11

 – 

12

*

DC Modular Power Unit Exploded View and Bill of Materials

……………….………………………………….... 

13

*

AC Modular Power Unit Exploded View and Bill of Materials

………………………….…………………………

14

Using the Trash Can Dumper

………………………………………………………………………………………. 

15

 

Record of Satisfactory Condition (TCD-M)

………………………………………………………………………….. 

16

 

Inspections (TCD-M)

………..........................................................................................................................

16

 

Record of Satisfactory Condition (TCD-U)

…………………………………………………………………………… 

17

 

Inspections (TCD-U)

……………………………………………………………………………………………………

17

 

Troubleshooting

…………………………………………………………………………………………………………

18

 

Labeling Diagrams

…...….............................................................................................................................. 

19

 

Limited Warranty

…………...…………………………………………………………………………………………… 

20

 

*NOTE: 

Trash can dumpers manufactured after 12-01-2018 receive a 2

nd

 generation modular power unit (MPU

GEN2). Diagrams and operating instructions for GEN2 power units are provided in separate MPU-AC/DC manuals.

*

 

 

 

Vestil Manufacturing Corp. 

2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 

Telephone: (260) 665-7586  -or-  Toll Free (800) 348-0868 

Fax: (260) 665-1339 

Web: 

www.vestilmfg.com

          Email: 

[email protected]

  

   TCD-M     

 TCD-U 

Содержание TCD Series

Страница 1: ...ine at http www vestilmfg com parts_info htm Table of Contents TCD M Specifications 2 TCD U Specifications 3 Signal Words 4 Hazards 4 Exploded Parts Diagrams and Bills of Materials 5 6 7 8 Power Unit...

Страница 2: ...2 101 cm 6411 16 165 cm 11313 16 289 cm 537 8 137 cm 483 4 124 cm 755 8 192 cm 400 lb 182 kg 554 lb 252 kg TCD M 60 AC 41 105 cm 779 16 197 cm 13411 16 343 cm 6511 16 167 cm 603 8 154 cm 755 8 192 cm...

Страница 3: ...4 165 cm 489 16 124 cm 755 8 192 cm 54 138 cm 64 163 cm 400 lb 182 kg 709 lb 322 kg TCD U 60 AC 41 105 cm 1401 4 357 cm 781 8 199 cm 5913 16 152 cm 755 8 192 cm 6513 16 168 cm 775 8 198 cm 400 lb 182...

Страница 4: ...he dumper before each use according to the inspection instructions on p 16 17 DO NOT use the TCD unless it is in satisfactory condition See Record of Satisfactory Condition on p 16 17 Apply both floor...

Страница 5: ...pin retainer 2 23 11103 Hex bolt gr A zinc plated 3 8 16 x 3 4 2 8 01 111 023 Bushing polygon 11 8 ID x 19 16 2 24 09 025 005 Handle formed 2 9 33456 Machinery bushing plain finish 11 8 x 10ga 6 25 34...

Страница 6: ...023 Bushing polygon 11 8 ID x 19 16 2 7 33456 Machinery bushing plain finish 11 8 x 10ga 6 23 34 516 009 Weldment bracket wheel cradle right 1 8 16 001 190 Floor lock adjustable height 2 24 34 045 03...

Страница 7: ...1 Stem caster PH F 8 2 S STM 2 18 37275 3 4 10 top lock nut zinc plated gr C 2 6 33 112 034 Clevis pin zinc plated 3 4 x 33 4 2 19 99 024 003 Guard cover endcap plug 2 7 34 612 004 Weldment pin retain...

Страница 8: ...xible vinyl cap 2 6 01 111 023 Bushing polygon 1 1 8 ID x 1 9 16 2 19 15 025 006 Grip handle 2 7 33456 Machinery bushing plain finish 1 1 8 x 10ga 6 20 32416 Thread cutting screw slotted type F zinc p...

Страница 9: ...oses and the chute remains stationary until pressure is reapplied to the system Hydraulic fluid HO150 hydraulic fluid To replenish the fluid add anti wear hydraulic fluid with a viscosity grade of 150...

Страница 10: ...to escape from the bleeder valve jog the motor several more times Wait at least 5 seconds between successive jogs Close the valve once air no longer is heard or seen bubbling out of the valve At this...

Страница 11: ...l components are represented with the chute in home location i e resting lowered position 115VAC Electrical Circuit Diagram 99124026 Rev D See NOTE in Table of Contents on cover page In this diagram a...

Страница 12: ...on Overcurrent and short circuit protection should be provided by the end user in accordance with recommendations and requirements in NEC NFPA 70 and local codes 3 phase electrical circuit diagram 991...

Страница 13: ...2 10 15 533 014 23 black 4 AWG battery cable 1 27 23255 33687 Bolt socket head 5 16 18x1 Washer lock 5 16 4 4 11 23305 33688 33008 3 8 16x1 socket head bolt 3 8 lock washer 3 8 flat washer 2 2 2 28 15...

Страница 14: ...1 16 ZB2BZ009 Contact block base 2 7 23255 33687 5 16 18 x 1 socket head bolt 5 16 lock washer 4 4 17 ZB2BE101 Contact block n o 2 8 01 116 003 Breather vent brass fitting 1 18 ZB2BA2C Operator black...

Страница 15: ...the top of the bin To slide a retainer down a rail simply press on the retainer To slide a retainer up a rail release the clamp and then move the retainer Step 3 TCD M units only Push the trash bin b...

Страница 16: ...chute Look for cracks damaged welds severe wear and corrosion Cylinder and limit switches Cycle the chute through a complete dumping sequence fully rotated and back to the ground When the chute reache...

Страница 17: ...chute Look for cracks damaged welds severe wear and corrosion Cylinder and limit switches Cycle the chute through a complete dumping sequence fully rotated and back to the ground When the chute reache...

Страница 18: ...tates counterclockwise b Consult factory for replacement c Ensure reservoir is filled 3 Motor hums chatters or buzzes or some type of squeal can be heard but the chute either does not move or only mov...

Страница 19: ...partment D Label 287 on nosing of a step C Label 220 applied to both side guards A Label 725 applied to both sides of chute B Label 212 on frame A C D B A D B C Modular Power Unit MPU The labels shown...

Страница 20: ...ulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How...