Parameter Settings (DMSC)
Parameter
Parameter Description
Setting
Setting Description
0-03
Start-Up Display Selection
d 2
Display the content of user-defined unit.
0-05
User Defined Coefficient K
d 0.3
Scales the frequency value so the display shows the
approximate turntable rpm.
1-02
Maximum Output Voltage
d 255
Sets the maximum voltage to the motor
1-07
Upper Bound of
Frequency
d 65
Sets the maximum rotation speed with the speed knob turned
fully clockwise (about 11 rpm).
1-08
Lower Bound of
Frequency
d 15
Sets the minimum rotation speed with the speed knob turned
fully counterclockwise (about 3 rpm).
1-09
Acceleration Time 1
d 10
Time to accelerate the motor to the drive's maximum output
frequency set point, in seconds.
1-15
Auto Acceleration /
Deceleration
d 0
Allows for a linear acceleration rate of the motor.
1-16
S-Curve in Acceleration
d 7
Determines how smoothly the drive accelerates.
2-00
Source of Frequency
Command
d 3
Allows the turntable speed to be controlled by the knob of the
drive's keypad.
2-01
Source of Operation
Command
d 1
Makes the drive turn on the external foot switch.
2-02
Stop Method
d 1
Allows the turntable to coast to a stop.
6-02
Over-Current Stall
Prevention Level
d 150
Sets the maximum motor current, as a percentage of the
drive's rated output.
6-03
Over-Torque Detection
Mode
d 3
Detection is enabled during Acceleration and continues until
the Continuous Output Time Limit is reached.
6-04
Over-Torque Detection
Level
d 200
Sets the maximum output torque, as a percentage of the
drive's rated output.
6-05
Continuous Output Time
Limit
d 10
Determines the time the drive will run after over torque is
detected, in seconds.
7-00
Motor Rated Current
d 120
Affects the point at which the drive limits its output current, in
percent of drive's rated output.
7-01
Motor No-load Current
d 75
Affects the drive's motor slip compensation.
7-02
Torque Compensation
d 10
Controls the motor's maximum start-up torque.