Inspections & Maintenance: 

Refer to diagram on p. 5 as well as Exploded View on p.4.

 

Inspect the carrier at least once per month or once per week for units used continually every day. 

Compare the condition of the carrier to the record to determine if it is in normal condition. If the 
inspection reveals problems, do not use the carrier until it is restored to normal condition.  

Frame: Examine the frame for damaged welds and fasteners, metal fatigue, and severe

rusting/corrosion. The structure should be clean, square and rigid, and free of rust and corrosion.  
Remove dirt and debris. If the paint/powder coat finish is chipped, clean the affected areas and apply 
touchup paint. 

Cylinder clamp mechanism: Examine both clamp jaws. Check the rubber pads for severe wear,

cracks, etc. Look for cracks in the link arms—particularly around bolt holes—as well as for bends. 
Check for damaged fasteners. Tighten connections as necessary. 

Check the wheels and (locking) caster. Confirm normal operation and condition.

Handle and linkage: Check for bends, cracks, etc. Move the handle up and down. Confirm that it and

both linkages are in normal condition. Tighten fasteners and joints as necessary. 

Labels: Confirm that all labels (shown in the 

Labeling diagram

) are present, undamaged and easily

readable. 

 

 

A (Label 287) 

B (Label 286) Side of handle 

C (Label 208) Outside face of both linkages 

D (Label 658) Base of frame 

Labeling Diagram: 

 

Each unit should be labeled as shown in the diagram. However, label content and locations are 

subject to change so your product might not be labeled exactly as shown. Compare the diagram 
below to your 

Record of Normal Condition

. If there are any differences between actual labeling and 

this diagram, adapt the diagram to reflect actual labeling. Replace all labels that are damaged, 
missing, or not easily readable (e.g. faded). To order replacement labels or to inquire whether your 
unit is properly labeled, contact the technical service and parts department online at 

http://www.vestilmfg.com/parts_info.htm

 or by calling (260) 665-7586. Ask the operator to connect 

you to the Parts Department.

 

 

Содержание OCC-2

Страница 1: ...s and mandatory standards applied where the product is used Replacement Parts and Technical Assistance For answers to questions not addressed in these instructions and to order replacement parts label...

Страница 2: ...pyright 2017 Vestil Manufacturing Corp 2 of 7 Specifications Dimensions net weight and capacity of standard models appear in the following diagrams and table Capacity 200 lb 90 9 kg Net weight 143 lb...

Страница 3: ...of this product could result in serious personal injuries or death Read the entire manual before installing using or servicing this product Read the manual to refresh your understanding of proper use...

Страница 4: ...S SWB swivel caster with brake 1 7 36109 Hex nut grade A plain finish 1 2 13 2 8 99 112 006 Pin clevis zinc plated 0 374 x 45 8 1 9 21 113 021 Spacer bearing shaft 4 10 11113 Hex bolt grade A plain fi...

Страница 5: ...e carrier should only be used on even level conrete or asphalt surfaces Do not use the carrier on inclines 6 Apply the caster brake and release the cylinder by raising the handle Record of Normal Cond...

Страница 6: ...en connections as necessary Check the wheels and locking caster Confirm normal operation and condition Handle and linkage Check for bends cracks etc Move the handle up and down Confirm that it and bot...

Страница 7: ...otors hydraulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and bat...

Отзывы: