background image

ADDITIONAL INSTRUCTIONS 

WARNING!

! Working with or near lead batteries is dangerous.  Batteries contain sulfuric acid and produce  explosive  gases.  A battery

explosion could result in loss of eyesight or serious burns.

! Do not smoke or allow a spark or flame near batteries.  Charge batteries in locations which are clean, dry, and well-ventilated.

! Do not lay tools or anything metallic on top of any battery.  All repairs to a battery  must be made by experienced and qualified

personnel.

! When working with batteries, remove personal items such as rings, bracelets, necklaces, and watches.   Batteries can

produce enough energy to weld jewelry to metal, causing a severe burn.

! Always have fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.

! Operating the battery with a low battery voltage can cause premature motor contact failure.

! Do not expose the lift or charger to rain or adverse conditions.

! Replace defective cords or wires immediately.

! Check the battery's water level frequently.

BATTERY CHARGER OPERATING INSTRUCTIONS:

Never operate the charger with either of the cables coiled.  Operating the unit with the cord wrapping around itself can cause
the cord to overheat, melt, and cause a short-circuit or a fire.

Plug the charger into a standard 115V receptacle.  If an extension cord must be used, keep it as short and as large as possible.
A small cord will decrease the output of the charger due to the voltage in the line.  This will increase the charging time.  It can
also cause the 115V cord to overheat.

When properly connected, the charge LED will indicate the status of charge flowing to the battery, as follows:

Red only - the charger is providing full output to the battery.

Both red and green - the charger is "topping off" the battery.

Green only - the charger is providing a "float," or maintenance, charge.

Remember to unplug the charger before moving  the equipment.  Failure to do so could cause damage to cords, receptacles,
and other equipment.

TROUBLESHOOTING:

If the unit does not operate, check all the wiring connections to make sure they're both mechanically and electrically sound
- specifically at the battery, the motor, and at any location a wire is connected to the chassis.  Also make sure the quick-connect
plug on the end of the pendant control cord is plugged in correctly.

CART-500-LA

, Manual.doc

 

Page 

1 of 

6

 

Page 

1 of 

6

 

Page 

4

 of 

6

 

Отзывы: