LOADING  INSTRUCTIONS

The  load  capacity

,  which

  appears  on  the 

data label (see

 p. 11, label 287) of your unit, is

 the 

net 

maximum  weight  the  table  will  support.  All 

loads  applied  to  the  table  must  be  centered  and 

evenly  distributed,  and

  assum

es

  the  load  is 

centered. 

  DO  NOT  exceed  the  capacity

 

becau

s

e

 

permanent damage or injury m

ight

 

occur

.

OPERATING  INSTRUCTIONS

  This  unit  is  equipped  with  a  constant 

pressure ("deadman" type) push button controller. 

The  buttons  are  marked,  "RAISE"  and  "LOWER".  

Press the  "RAISE"  button  to  elevate  the  deck  of 

the  table.  When  the  button  is  pressed,  the 

motor  air  supply  valve  opens  and  air  pressure 

causes the cylinder to extend. Cylinder extension 

raises  the  deck.  Always  stand  to  the  side  of  the 

table while operating the cylinder and 

keep

 clear 

of moving parts.  The platform will rise as long as 

the "RAISE" control is pressed.

 When the button is 

released,  the  deck  will  maintain  its  present 

position. Releasing the button allows the valve to 

close and prevents further air flow, i.e. closes the 

pilot-operated motor air supply valve.

P

ressing  the  "LOWER"  control

  button 

energizes

 the lowering  solenoid valve. Th

is allows 

the

  cylinders

  to

  retract  as  oil  returns  to  the 

reservoir

.

 

As with the RAISE button,

 releasing the 

LOWER  button

 

causes  the  deck  to  stop  moving 

and to 

main

tain

 

its current

 elevation.  Be certain 

no  person  or  object  is  in  the  way  wh

ile

  the  unit  

descend

s

.

I

f

 the unit is overloaded, 

the deck

 will not 

rise

.  Instead,

  the  relief  valve  will  open  due  to 

excessive pressure buildup an

s

 oil will bypass

 the 

cylinder and flow

 into the reservoir.

  Always  remember

:  1) 

the  motor 

operates

  only 

wh

ile

  the  "RAISE"  button  is  pressed

;

  and 

2) 

the 

lowering solenoid valve is energized only wh

ile

 the 

"LOWER" button is pressed.

SAFETY INSTRUCTIONS TO THE OPERATOR

1.) Always center and evenly distribute loads 

placed on the table.

2.)

    DO NOT

 use the 

table

 if repairs

 are necessary.

         Only use the table if it is in normal operating

         condition.

 

3.)

    Tag the unit "Out of service" and n

otify

         

maintenance personnel i

f

 

you notice anything

         unusual during operation, such as binding,

         odd pump noises, etc.

4.) Do not continue to press the "UP" control if 

the unit does not elevate.  

The motor and/or 

pump

 

might be

 permanently damage

d as a 

consequence.

ORDERING REPLACEMENT OR EXTRA PARTS

    Vestil  Manufacturing  Co.  company  is 

committed to using high quality parts in all of our 

products.  Vestil  is  not  responsible  for  any 

equipment  failure  that  results  from  the  use  of 

unapproved  replacement  parts.  To  order 

replacement  (or  spare)  parts  contact  Customer 

Service at the telephone number of email address 

published on the cover page of theis manual.  To 

expedite your request, be prepared with the serial 

number of your table, which appears on the data 

label (#287 on p. 11). Only refer to part numbers 

listed in this Owner's Manual.

Содержание AHLT Series

Страница 1: ...power unit requires a minimum air supply of 70 CFM at 70 PSI AHLT SERIES AIR HYDRAULIC SCISSOR TABLES OWNER S MANUAL Revised11 13 A company dedicated to solving ergonomic and material handling problems since 1955 AIR HYDRAULIC SCISSOR TABLE MODEL AHLT Website www vestil com Ergonomic Solutions Contents Safety Precautions 1 Operation 1 4 Installation Instructions 2 Pneumatic Hydaulic Circuit Diagra...

Страница 2: ...a level even surface a Anchor the table to the floor with appropriately matched anchor bolts b Measure the diameter of the bolt holes in the base of the frame and install bolts that are at least 4in long to anchor the table to the floor c Shim the table to level it Grout under the base of the table to provide additional resistance to warping and bending forces applied to the base between shims Gro...

Страница 3: ...ontrols the lowering speed of the table It is preset and cannot be changed Releasing the LOWER control button deenergizes the solenoid and closes the valve poppet This prevents oil from returning to the reservoir and consequently the cylinders stop retracting The deck will maintain its elevation Cartridge Valves The lowering valve as discussed above is of cartridge construction and is virtually ma...

Страница 4: ...s current elevation Be certain no person or object is in the way while the unit descends If the unit is overloaded the deck will not rise Instead the relief valve will open due to excessive pressure buildup ans oil will bypass the cylinder and flow into the reservoir Always remember 1 the motor operates only while the RAISE button is pressed and 2 the lowering solenoid valve is energized only whil...

Страница 5: ...5 HYDRAULIIC LINE AIR SUPPLY LINE AIR PILOT LINE PNEUMATIC HYDRAULIC CIRCUIT DIAGRAM NOTE Operation of this machine without a filter lubricator will void the warranty ...

Страница 6: ...6 AHLT SREIES AIR HYDRAULIC SCISSOR TABLES ...

Страница 7: ...ESCRIPTION CYLINDER MOUNT SPRING PIN CYLINDER MOUNT PIVOT PIN CYLINDER MOUNT BEARING HYDRAULIC CYLINDER CYLINDER SEAL KIT NOT PICTURED ROLLER PIN ROLLER ROLLER BEARING ROLLER WASHER ROLLER SNAP RING HINGE PIN HINGE PIN BEARING PIVOT PIN GREASE ZERK PIVOT PIN BEARING PIVOT PIN ROLL PIN PIVOT PIN PIVOT PIN WASHER TOE GUARD HANGER NUT TOE GUARD HANGER WASHER TOE GUARD CORNER PIECE TOE GUARD ALUMINUM ...

Страница 8: ...se c Foreign material in flow control valve d Binding cylinders e Foreign material in velocity fuse a Correct as necessary b Add fluid Refer p 10 parts B1 and C for proper fluid level and type c DO NOT CHANGE RELIEF VALVE SETTING Instead reduce the load to rated capacity d Remove and clean e Inspect all fittings for proper fit f Remove and clean g Remove solenoid valve Check and clean Refer to p 3...

Страница 9: ...n press the down button d See 1 h e To unlock the fuse repressurize the hydraulic system f Refer to p 3 Velocity Fuse a Leaking hoses and or cracked fittings b Check valve is stuck open The combination of a stuck Check Valve and open Soleniod Valve will cause excessive speeds c Foreign material stuck in Flow Control Valve In this case table lowers initially at a normal rate then speeds up as the p...

Страница 10: ...il should be 1 to 1 1 2 below the top of the reservoir tank with the deck fully lowered Add oil if necessary 2 Check for oil leaks see Troubleshooting on p 8 9 Resolve the issue as described 3 Check roller bushings axle pins clevises and pivot points for severe wear 3 Check the hydraulic system for worn or damaged hoses Replace damaged hoses as necessary 4 Inspect each roller for looseness and sev...

Страница 11: ...11 LABEL PLACEMENT DIAGRAM ALL LABELS MUST BE UNDAMAGED AND READABLE ORDER REPLACEMENT LABELS WHEN NECESSARY Copyright 2013 Vestil Manufacturing Co ...

Страница 12: ...s defects in the following original dynamic components motors hydraulic pumps electronic controllers switches and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How long is the warranty period The warranty period for original components is 1 year The warranty period begins on the dat...

Отзывы: