G
P R O · LL-ME-BAT/I-24/0,6 Nm RB IO-AIR
–
Briefly press the PROG. button at the motor-
head. Programming mode is now active for
60 sec. while the green LED flashes continuously.
–
Press PROG. button at the back side of the
remote control.
–
LED starts flashing.
–
Press ON/UP button of the channel for pro-
gramming shortly.
–
The motor will give a feedback (two short
UP / DOWN movements) to confirm that the ins-
tallation procedure has ended.
The flashing of the LED on the back side stops
after 1 second.
–
To drive the motor in UP or DOWN direction,
please press the respective button. Motor moves
with a delay, since no final positions are set.
Programming for initial operation respectively after RESET
–
Briefly press the PROG. button at the motor-
head. Programming mode is now active for
60 sec. while the green LED flashes continu-
ously.
–
Press PROG. button at the back side of the
remote control.
–
LEDs on the front side of the remote control
start flashing.
–
Press and release the STOP button short-
ly. The motor will give a feedback (two short
UP / DOWN movements). Programming was
successful. The flashing of the LEDs on the
front side of the remote control stops after
about 1 sec., then the motor can be driven.
–
To drive the motor in UP or DOWN direction,
please press the respective button. Motor moves
with a delay, since no final positions are set.
PROG. button
at the back side
Radio remote control IO-AIR Transmitter
Radio wall transmitter IO-AIR Switch
PROG. button
LED
– Hold down the button
or
to check the motor turning direction.
– When the motor reacts in opposite direction (when motor goes down
when you press UP and vice-versa), you need to change the motor
direction. Motor direc tion can only be changed during installation phase,
when no limit positions are set.
– Shortly press the following combination of buttons (within 10 seconds):
– The motor will give a short feedback if the process is finished.
Changing motor turning direction
Setting electronic limit position
ATTENTION!
The motor starts to move with a short delay time during instal-
lation phase, when no limit positions are set.
Ä
– Hold down the button
to move the motor in the requested
lower
limit position.
For precise moving of the motor briefly press the button
, press
again and hold.
– Press the following button sequence (within 10 seconds): 5 × short
.
– The motor will give a short feedback if the process is finished.
Setting the lower limit position
– Hold down the button
to move the motor in the requested
upper
limit position.
For precise moving of the motor briefly press the button
, press again
and hold.
– Press the following button sequence (within 10 seconds): 5 × short
.
– The motor will give a short feedback if the process is finished.
Setting the upper limit position
The installation procedure is finished and the limit position settings are
saved.
– Press the button
or
= self-locking.
– Press the opposite button or STOP button of the radio remote control
to stop the drive.
Precise controlling with set limit positions
– Hold down the button
or
.
The motor now moves at a slower speed and can thus be precisely
steered to the desired position.
– After releasing the directional button, the motor is immediately stopped.
NOTE:
The function is only available when the limit positions have been
set completely.
i