36
Installation
Air piping
CAUTIONS
REMEMBER
Always use a pressure-resistant air hose.
Failure to use a pressure-resistant air hose could result in ruptures or air leaks.
Applicable air / nitrogen
This eraser requires clean compressed air (CDA) or N2 gas for air blow operation.
Supply air within the pressure range of 0 to 0.5 MPa.
Use an air drier to remove any moisture. (Dew point temperature -15 °C or less)
Use a mist separato
r (0.3 μm) to remove any impurities.
Supply air within the temperature range of 0 to 40 °C."
to SH series
Applicable hose
Use a pressure-
resistant air hose (outer diameter Φ6 mm × inner diameter Φ4 mm)
Connecting the hose
A one-touch hose joint (air supply port) is provided on the end of the bar unit.
Connect the hose to this joint.
Operation
Operation
CAUTIONS
DISASSEMBLY
PROHIBITED
Do not modify or disassemble the eraser.
There are very dangerous high-voltage parts inside.
PROHIBITED
Do not block any opening such as the inlets or outlets.
There is a risk of failure.
PROHIBITED
Do not insert metal or foreign objects into the openings.
There is a risk of electric shock or failure.
UNPLUG
Always stop the power supply when not using the eraser for a long time.
The insulation could degrade and result in electric shock, failure or fire.
Содержание Stat-Clean SH Series
Страница 6: ...6 外観寸法 バー本体 SH 16 バー本体 SH 20 ...
Страница 7: ...7 外観寸法 バー本体 SH 30 バー本体 SH 40 ...
Страница 8: ...8 外観寸法 バー本体 SH 50 バー本体 SH 60 ...
Страница 9: ...9 外観寸法 バー本体 SH 70 電源ユニット SH G3 ...
Страница 10: ...10 外観寸法 分岐ボックス SH SP2 ...
Страница 26: ...26 External View Bar unit SH 16 Bar unit SH 20 ...
Страница 27: ...27 External View Bar unit SH 30 Bar unit SH 40 ...
Страница 28: ...28 External View Bar unit SH 50 Bar unit SH 60 ...
Страница 29: ...29 External View Bar unit SH 70 Power supply unit SH G3 ...
Страница 30: ...30 External View Junction box SH SP2 ...