background image

14 

For Your Safety

 

Safety Precautions 

●Carefully read these 

Safety Precautions before use. Observe the precautions indicated herein to ensure 

safety. 

●Safety precautions in this instruction manual are categorized into two types by the degree of danger 

associated with each of the followings. Based on danger analyses performed by Vessel, all precautions in 
this instruction manual are of the CAUTION level. 

●If the equipment is used in a manner not specified by the manufacturer, the protection provided by the 

equipment may be impaired. 

WARNING 

Indicates that improper handling can lead to serious injury or even death. 

CAUTION 

Indicates that improper handling can lead to minor injury and property damage. 

 

 

This symbol indicates a WARNING or CAUTION. 

 

This symbol indicates a prohibited action. 

 

This symbol indicates a mandatory required action 

 

CAUTIONS

 

 PROHIBITED 

Do not use the F120R-E in environments that require explosion-proofing.     
The F120R-E is not of explosion-proof construction; therefore explosion or fire may 
occur. 

 PROHIBITED 

Do not use the F120R-E in flammable atmospheres. The corona discharge can act 
as an ignition source and cause an explosion or fire. 

 PROHIBITED 

Do not use the F120R-E in environments subjected to sharp temperature fluctuations 
or dewing. This kind of environment can lead to breakdown. 

 DO NOT WET 

Do not use the F120R-E in highly damp places or anywhere it may be wet by water, 
oil,  solvent  or  other  liquid.  Contact  with  moisture  can  result  in  electric  shock  or 
breakdown. 

 PROHIBITED 

Do not use the F120R-E for any other purpose than static erasing or dust removal. 

 PROHIBITED 

Do  not  use  the  F120R-E  with  power  supplies  of  ratings  not  specified  in  the 
specifications. Inappropriate power supplies can result in fire and electric shock. 

 PROHIBITED 

Do not install, use or service the F120R-E until having understood the information in 
this instruction manual. 

  REMEMBER 

Keep this instruction manual in a safe handy place for future reference. 

  CAUTION 

VESSEL assumes no responsibility whatsoever for consequences arising from the 
use of this product. 

 

 Product Features

 

■AC type corona discharge

 

• This is an AC corona discharge type ionizer. The ion balance is not disturbed by needle contamination. 
• A high-frequency piezoelectric transformer is incorporated. Losses caused by recombination of ions are 

reduced, and ions are generated efficiently. 

■Fan type ionizer

 

• The powerful 120 mm square DC fan feeds ionized air to remote places. 
• The fan’s airflow volume can be adjusted in three steps. 
• The airflow direction can be changed vertically by adjusting the stand’s screw. 
• Components are assembled into the compact body to create a small and lightweight product. 
• The input power is 24 VDC. Power is supplied to the product from the enclosed dedicated AC adaptor. 

■Capacitive

-coupled discharge 

• The capacitive-coupled method applies a high voltage onto the discharge needle, thus providing 

outstanding ion balance stability. 

 

 

Содержание Stat Clean F-120R-E

Страница 1: ...re reference Table of Contents For Your Safety Product Features Production Specifications External View Performance Installation Before Use Operation Maintenance Troubleshooting Storage Warranty Instruction Manual Read this instruction manual before use Keep it in a safe handy place for future reference P 14 P 15 P 15 P 16 P 17 P 17 P 18 P 19 P 21 P 23 P 23 P 24 ...

Страница 2: ...places or anywhere it may be wet by water oil solvent or other liquid Contact with moisture can result in electric shock or breakdown PROHIBITED Do not use the F120R E for any other purpose than static erasing or dust removal PROHIBITED Do not use the F120R E with power supplies of ratings not specified in the specifications Inappropriate power supplies can result in fire and electric shock PROHIB...

Страница 3: ...ns Ionizer Product Number F120R E Model F 120 Ion generation method High voltage AC corona discharge Output voltage AC 10 kV p p Input voltage DC 24 V 5 700 mA max Dimensions H198 W162 D69 5 mm including stand Weight 0 9 kg Fan speed 3 66 m3 min Max fan speed Blow speed 5 0 m s HI 4 4 m s MD 3 9 m s LO Noise emission 61 dBA max and straight airflow without filter measured at 1m actual measured val...

Страница 4: ... temperature humidity 0 40 C 10 85 RH No dewing or freezing Cable length DC output cable approx 1 8 m AC input cable approx 1 8 m Weight 135 g Consumables Electrode Needle Unit F 120RCH The measurement values were obtained using the VESSEL measurement environment so errors could be induced depending on the operation environment External View F120R E ...

Страница 5: ...ectric shock and static electricity removal troubles REMEMBER Install the F120R E securely The F120R E can be damaged or malfunction if it is dropped REMEMBER Install the F120R E based on environments stated below Adverse environments cause product deterioration and breakdown Humidity 35 65 RH No dewing Temperature 5 40 Humidity 50 angle airflow at HI fan speed They represent the central tendency ...

Страница 6: ...nt screws located on the left and right sides of the stand Phillips screw M6 Securely tighten the adjustment screws after adjustment Keep objects from getting in between the F120R E and the target area Before installing the F120R E check the strength of supporting structure Please keep backside of the F120R E away from the object and keep away from the wall surface at least 100mm for the proper fu...

Страница 7: ...e supplier for servicing to avoid accidents Operation Power Power is turned on by pressing the Power switch H V lamp and fan lamp light up in green and then the unit start the operation When you press the power switch again power is turned off Fan speed The fan s airflow volume can be adjusted in three steps LO MD HI Please adjust the air with the Airflow switch Variable louver The airflow directi...

Страница 8: ...ts are adhered to the fan remove them switch on the power again and make sure that the lamp is off If the alarm lamp light in red again even though the causes are resolved contact the supplier for servicing to avoid accidents Immediately after turning on the power there is a moment that the fan lamp glows red This is not a malfunction When externally outputting the alarm signal The lights and othe...

Страница 9: ...periodical cleaning 1 Be sure to turn the power switch off to stop the operation 2 Unplug the power supply adapter from the electrical outlet 3 Remove the screw that secures the front cover 4 Removing the front cover 5 Wipe it with a dry soft cloth Be careful not to stick yourself on the needles 6 Reinstall the front cover When cleaning the front cover CAUTION CLEANING A dirty front cover could lo...

Страница 10: ...d Be sure to periodically clean or replace the filter 1 Before cleaning the filter stop operation of the F120R E turn off power 2 Unplug the AC adapter or pull out the wires from input output terminals 3 Take out the filter cover 4 Remove and clean the filter Make sure the falter is completely dry before reuse Installing the filter while still wet may damage the F120R E 5 Wipe off the dust adhered...

Страница 11: ... following cases contact the supplier for servicing Do not service the F120R E by yourself to avoid accidents The power lamp does not light when the power switch is in the ON position Air is not blown when the airflow switch is turned When the F120R E is moved during operation sometimes airflow comes out or sometimes not The power cable is excessively hot The power supply adapter is excessively ho...

Страница 12: ... accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tor...

Отзывы: