2 5
■
Names and Functions
1) Fan malfunction LED
: The FAN ALARM LED illuminates if the fan stops and fan lock is
detected.
2) High pressure
abnormality warning LED
: The H.V. ALARM LED illuminates if the high pressure output stops.
3) Airflow adjustment
: Used for adjusting the airflow of the fan. The airflow can be adjusted
continuously.
4) Power LED
: Check that the power is turned ON/OFF.
5) Power switch
: Used for turning the power ON/OFF.
6) Rough filter, filter cover
: A filter to prevent dust suction.
7) Stand adjusting hole
: Used for adjusting the height of the body.
8) Angle adjusting knob
: Used for adjusting the angle of the body.
9) Stand
: Used for installing the body on a table or a structure.
10) Power connector
: A connector for input power of 24 V DC.
11) Ground terminal
: A terminal for grounding connection.
12) Alarm output
: Used for external output of alarm signals.
13) Cleaning brush
: Used to remove dust or dirt adhering to the needle electrode.