VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 156060 Fax: 02380 261204 E-mail: [email protected] Web: www.ves.co.uk
Supply Unit
Installation, Operation and Maintenance Manual
14
ORIGINAL INSTRUCTIONS
®
Maintainance
6
Colourfan
units feature plug & socket connections to allow easy fan assembly removal should it
be required. Follow the instruction below.
Ensure the unit is fully isolated from the electrical supply. Carefully remove the lid by
unfastening the side catches around the casework. Separate the plug connection by hand (tools
not required)
by lifting the locking lever and pulling the plug/socket apart
22
.
DO NOT
pull the
cable to separate the assembly . Remove and retain the four fan plate fixings . Carefully
lift out the fan assembly; removal of the fan plate cover is not normally required.
Fan assembly
removal
Important
Warning
Before attempting to carry out any work on our units, all accompanying documentation
including warning labels on the unit must be referenced.
Should it be necessary to remove any component, ensure that these are resecured into position
once reinstalled. It is critical that after any maintenance work has been conducted that all
components removed/replaced be refitted correctly by a competent engineer.
When accessing the unit ensure the access panels/lids are handled/opened in a controlled
manner so as to avoid damage to the unit or injury to personnel. This is particularly important
with bottom access units.
Care should be taken with larger unit lid removal as this may need to be undertaken by more
than one person.
Caution
Before attempting to carry out any maintenance work, investigative or repair work on our units,
the unit
MUST BE COMPLETELY ISOLATED
from its electrical supply. Ensure a minimum of two
minutes after electrical disconnection before removing access panels. This will allow any moving
parts to come to a rest. When used in conjunction with an Inverter for speed control, a minimum
of
Five minutes
should be given to allow for the capacitors to discharge before starting work.
Care should also be taken when accessing external units as the wind and elements may cause
moving parts to windmill.
Replace the fan assembly onto the fan bulkhead; a small stud has been included to assist with
correct location. When returning the fan assembly to the case take care not to drop the fan
impellor on the inlet eye as incorrect alignment may damage the impellor. Secure the fan plate
with the appropriate fixings, ensuring correct fan aligment with the inlet eye, adjusting as
necessary
25
. A trial spin by hand should indicate if the fan is rubbing. To align, losen the fan
plate fixings, adjust and retighten. It is important that the loom is secured away from the fan
impellor (coil excess cable and zip tie loom to fan plate as appropriate), allow enough slack for
loom connection/removal to fan socket. On reconnection, the plug assembly features a locating
lug to ensure correct orientation. Once rejoined, lock the connection together again using the
locking lever as shown
22
. Carefully replace the lid and ensure all fixings are safely refastened.
24
23
Fan assembly
installation
Plug connector
locking/Unlocking
Fig.
22
23
23
22
lifting Hazard:
Due the size and weight of larger fans take extra care during removal/installation.
Multiple persons are advised for this operation to avoid injury.
Caution