AIRBEAM Wall Extract Units

Installation, Operation and Maintenance Manual

ORIGINAL INSTRUCTIONS

Therm

TO

TO

L1

L2

L3

E

V

io

le

t

V

io

le

t

O

ra

n

g

e

B

ro

w

n

R

e

d

B

lu

e

G

re

y

B

la

c

k

G

rn

/Y

lw

 

!

 

 

!

 

!

3

Standard motor wiring arrangement

Fig.7   

400V 3Ph 50Hz

Note

:  A trial connection of the three phase (3Ph) supply should

be made to check that the fan rotates in the correct direction as
indicated on the fan. If the rotation is incorrect, interchange any
two phases of the incoming supply at the terminal block.

3

Wiring 

continued

Standard motor wiring arrangement

Fig.8  

230V 1Ph 50Hz

N

L

E

Cap

B

ro

w

n

W

h

it

e

B

la

c

k

G

rn

/Y

lw

Therm

Aux

Main

G

re

y

O

ra

n

g

e

O

ra

n

g

e

 

IMPORTANT

Before attempting to carry out any work on our units, the unit

MUST BE COMPLETELY ISOLATED

 from its electrical supply.

Ensure a minimum of two minutes after electrical
disconnection before commencing work. This will allow any
moving part to come to a rest,  all accompanying
documentation including warning labels on the unit must be
referenced

WARNING

When used in conjunction wih an Inverter for speed control, a
minimum of 5 minutes should be given to allow for the
capacitors to discharge before starting work

Care should also be taken whilst cleaning the unit in the
event that wind or air movement should cause the fan to
freewheel.

Annual checks

Check inside the unit for an accumulation of dust, grease
etc. If the fan impeller is heavily soiled, clean out carefully
(ensure the unit is properly isolated). Failure to do this
periodically could lead to a loss of performance or the fan to
become out of balance, leading to bearing failure. Check the
drainage holes (cowl unit only) are clear of debris and
service as required. Clean the external louvre/cowl to ensure
that performance is maintained. Inspect the backdraught
shutters for signs of damage (cracks or bending).

IMPORTANT

When removing the louvre/cowl please note that these
fixings secure the units into position and by removing these
the unit may be released from the wall. This is particularly
important with the cowl unit as the backdraught plate would
be unsupported.

PLEASE ENSURE THAT THIS DOCUMENT IS
PASSED ON TO THE END USER.

We reserve the right to alter the specifcation without notice

 

When enquiring after or ordering spares contact VES
Customer Services Department, quoting the sales order
(SO) number and unit type as found on the unit nameplate.

Telephone

08702 40 43 40

Fax

08702 40 45 50

!

5

Maintenance

In general, this series of units require very little maintenance.
All fan and motor bearings are supplied fully greased,
lubricated and sealed for life. In the unlikely event of
component failure, spares are available from stock at VES
Andover Ltd.

!

IMPORTANT

When used in conjunction with a speed controller refer to
the appropriate controller wiring diagram

IMPORTANT

When used in conjunction with a SC310SD speed controller
additional wiring connections will be required - refer to the
appropriate controller wiring diagram or document ID
Ref:678 for further details*.

N