Alignment Requirements

The proximity of the magnet to the sensor is important for 

proper detection. The alignment arrows on the sensor and the 

magnet must point to each other and the gap between them 

must not exceed .25 inch (6.4mm) in any direction.

Alignment Guidelines

gap is 1/4” (6.4mm) 

or less

misaligned

arrows

gap is too wide

Front View

End View

Installing

1.  Based on your requirements, decide where you want to in-

stall the sensor and the magnet. For door installations, locate 

the sensor:  

 

• On the knob side of the door jamb, away from hinges. 

• At least 1 ft. (30 cm) above the floor to avoid damage.

 

 

For window installations, make sure the location does not 

expose the sensor to contact with water.

2.  Follow the alignment requirements that are described in the 

Planning section.  

 

NOTE: For easy access and handling, it is recommends that 

the sensor be linked to a transceiver before installing it, see 

the Linking section.

3. 

Install the sensor on the interior side of the fixed frame. 

A.  Remove the mounting  

bracket from the sensor. 

  

 

 

 

 

 

estimated time: 20 minutes

Tab lock

Notch

Tab lock

Notch

B.  Position the mounting bracket and mark the two mount-

ing screw drill points.

C. 

Insert the first screw loosely and level the mounting 

bracket.  

Notches

Notches

D. 

Install the second screw, and then hand-tighten the first 

screw.

E.  Snap the sensor onto the mounting bracket where the 

notches are located. 

Tab lock

Tab lock

F.  Slide the sensor on the bracket until it snaps into place 

on the tab lock.

4.  Install the magnet on the moving part of the door or win-

dow.
A. 

Use a screwdriver to press the tab lock and flex the mag

-

net cover to remove it. 

 

Tab lock

Tab lock

 

 

The cover is removed from the magnet body.  

 

 

 

Door/Window Sensor • Installation Guide

Содержание EDWS

Страница 1: ...ur 100 lux for 60 actuations hour Charge Time for Full Charge 21 hours 200 lux after startup 42 hours 200 lux cold start Operating Life in Dark ness after full charge 174 hours heartbeat only 67 hours 10 actuations hour 10 hours 100 actuations hour EEP EnOcean Equipment Profile D5 00 01 Maximum Sensor Gap 0 25 inch 6 4 mm Dimensions Sensor 3 15 L x 0 83 W x 0 59 D 80 mm x 21 mm x 15 mm Dimensions ...

Страница 2: ...cribed in the Planning section NOTE For easy access and handling it is recommends that the sensor be linked to a transceiver before installing it see the Linking section 3 Install the sensor on the interior side of the fixed frame A Remove the mounting bracket from the sensor estimated time 20 minutes Tab lock Notch Tab lock Notch B Position the mounting bracket and mark the two mount ing screw dr...

Страница 3: ... link message The awaiting transceiver receives and stores the link permanently so the devices can interact to provide a variety of intelligent control options Sensor Profiles The sensor profile determines how the sensor is used within the system whether it is for occupancy detection HVAC control or single load control How the sensor interacts with other devices depends on where it is installed an...

Страница 4: ...hooting Problem Solution Checklist The sensor does not generate a wireless message Verify there is a faintly audible click when the contact is closed and opened Verify the LED blinks once when the contact is closed and opened Verify the solar cell is charged properly Check that the magnet is oriented to the sen sor properly Check that the alignment arrows are not spaced more than 25 inch 6 4 mm Th...

Отзывы: