Electronic and automatic polymerizer

Rev.  10/2019

Instruction for use

a.gree srl

Via Retrone 14, Altavilla Vicentina 36077 (VI) Italy

+39 0444 960 991   [email protected] 

7/7

vertysystem.com

LEGEND

TEMPERATURE (45°C)

SINGLE BEEP

POLYMERIZATION

DOUBLE BEEP

END OF THE CYCLE

AUTOMATIC AIR 

DISCHARGE COMPLETED

LEGEND

TEMPERATURE (85°C)

SINGLE BEEP

POLYMERIZATION

DOUBLE BEEP

END OF THE CYCLE 

AUTOMATIC AIR 

DISCHARGE COMPLETED

DURATION

45 min.

15 min.

TOT.

60 min.

DURATION

20 min.

10 min.

TOT.

30 min.

P.1 | VERTYS PROTHESIS HOT

P.2 | VERTYS TEMPLUS

Ideal programme for heat curing full 

denture resins, charged with composite 

micro-pearls. For a very high quality 

polymerization set the pressure to 2 Bar 

and fill the chamber with at least 3/4 of 

water.

Ideal programme for cold curing 

temporary resins charged with 

composite micro-pearls. For a very 

high quality polymerization set the 

pressure to 2 Bar and fill the chamber 

with at least 3/4 of water.

LEGEND

TEMPERATURE (38°C)

SINGLE BEEP

POLYMERIZATION

DOUBLE BEEP

END OF THE CYCLE 

AUTOMATIC AIR 

DISCHARGE COMPLETED

DURATION

30 min.

10 min.

TOT.

40 min.

P.3 | VERTYS SURGICAL

Ideale programme for bite splints and 

surgical/radiological stents. For a very 

high quality polymerization set the 

pressure to 2 Bar and fill the chamber 

with at least 3/4 of water.

Содержание Apolix

Страница 1: ...the main air to the terminal labelled INPUT AIR on the back panel The input hole has a 6 Pressure must not exceed 6 bars Connect the 8 hose to the OUT output and unwind it to a water drain or a water...

Страница 2: ...10 C it s necessary to hold the RUN STOP button 2 for a few seconds to start a new cycle The new cycle will start after an acoustic signal Pressure will stay active until you manually release it Do no...

Страница 3: ...onsumption 1220 W 3 Tension category II 4 Actual chamber volume 1 5 l 5 Inside dimensions 140 h 145 mm 6 Maximum pressure 6 bars 7 Working temperature limits 40 C 120 C 8 Temperature and functioning a...

Страница 4: ...e at the same time for 3 seconds f Push the RUN STOP button to confirm 8 Regulate temperature t a Hold the temperature button a and set the desired temperature using the arrows e b Push the temperatur...

Страница 5: ...d set the second desired temperature using the arrows e b Push the temperature button a again to confirm 10 Regulate duration time du a Hold the timer button b and set the desired time using the arrow...

Страница 6: ...arrows e at the same time for 3 seconds The display f will say AIR 3 The pressure will be the same as the last used program 4 Release the air pushing the RUN STOP button temperature duration 2 tempera...

Страница 7: ...programme for heat curing full denture resins charged with composite micro pearls For a very high quality polymerization set the pressure to 2 Bar and fill the chamber with at least 3 4 of water Ideal...